Foreword 

 

1 Foreword 

1.1  Notes on the Documentation 

This description is only intended for the use of trained specialists in control and automation engineering 
who are familiar with the applicable national standards. It is essential that the following notes and 
explanations are followed when installing and commissioning these components. 

The responsible staff must ensure that the application or use of the products described satisfy all the 
requirements for safety, including all the relevant laws, regulations, guidelines and standards. 

1.1.1 Liability Conditions 

The documentation has been prepared with care. The products described are, however, constantly under 
development. For that reason the documentation is not in every case checked for consistency with 
performance data, standards or other characteristics. In the event that it contains technical or editorial 
errors, we retain the right to make alterations at any time and without warning. No claims for the 
modification of products that have already been supplied may be made on the basis of the data, diagrams 
and descriptions in this documentation. 

All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard. 

1.1.2 Trademarks 

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, EtherCAT P

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 

are registered trademarks of and licensed by Beckhoff Automation GmbH. 
Other designations used in this publication may be trademarks whose use by third parties for their own 
purposes could violate the rights of the owners. 

1.1.3 Patent Pending 

The EtherCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications 
or registrations in various other countries. 
The TwinCAT Technology is covered, including but not limited to the following patent applications and 
patents: EP0851348, US6167425 with corresponding applications or registrations in various other 
countries. 

1.1.4 Copyright 

©

 Beckhoff Automation GmbH & Co. KG. 

The reproduction, distribution and utilization of this document as well as the communication of its contents 
to others without express authorization are prohibited. Offenders will be held liable for the payment of 
damages. All rights reserved in the event of the grant of a patent, utility model or design. 

1.1.5  State at Delivery 

All the components are supplied in particular hardware and software configurations appropriate for the 
application. Modifications to hardware or software configurations other than those described in the 
documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. 

1.1.6 Delivery conditions 

In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply. 

C6670-0010 

Summary of Contents for C6670-0010

Page 1: ...Installation and Operating instructions for C6670 0010 Control Cabinet Industrial Server Version 1 2 Date 2018 11 23...

Page 2: ......

Page 3: ...2 2 Appropriate Use 9 2 3 Opening the Housing 9 2 4 Access to the battery 11 2 5 Access to the fans 12 2 5 1 Replacing the fans in the area of the interfaces 12 2 5 2 Exchanging the fan cartridge 13...

Page 4: ...ff 20 4 1 1 Switch on 20 4 1 2 Shutting down and switching off 20 4 1 3 First switching on and driver installation 20 4 2 Servicing and maintenance 21 4 2 1 Cleaning of the Industrial PC 21 4 2 2 Main...

Page 5: ...and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could viol...

Page 6: ...als Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety...

Page 7: ...the fieldbus connection plug uncouples the PC optional Items of equipment that have been switched off must be secured against being switched on again The Industrial PC s power supply unit must be sup...

Page 8: ...ing Attention The operator is responsible for ensuring that only trained electrical staff opens the housing of the Industrial PC 1 4 1 National regulations Depending on the type of machine and plant i...

Page 9: ...available for several camera interface cards for video evaluation All connections of the Industrial Server face upwards so that the connecting cables can be taken directly to the wiring channel The s...

Page 10: ...Server for control cabinet installation all slots for full size plug in cards 2 removable frames for hard disks drives and plug in cards easily accessible all connectors on the top detailed PC config...

Page 11: ...Industrial Server must not be used where there is a risk of explosion 2 3 Opening the Housing Top view of the C6670 0010 The housing cover is locked by a latch After pressing the key 1 the cover can b...

Page 12: ...e taken off completely so providing access to the components The reassembly of the cover takes place in reverse order Ensure that the cover engages into the slides 2 Removing the card holder card hold...

Page 13: ...the housing 2 4 Access to the battery Removing the cover allows access to the battery Danger of Explosion WARNING The battery is a CR2032 type nominal voltage 3 0 V from e g Panasonic or Sanyo Replac...

Page 14: ...fans in the area of the interfaces Identical fan type Attention Replace the fans only with the identical type or an alternative type approved by Beckhoff Remove the housing cover Note For exchanging...

Page 15: ...hoff For exchanging the fan cartridge 1 first solve the knurled screw 2 Opening the fan cartridge 2 1 The cartridge can then be folded down and taken out Removing the fan Disconnect the supply cable f...

Page 16: ...rted The power delivery is each limited to 900 mA 2 6 3 USB interfaces USB1 USB2 X110 X111 The two USB interfaces X110 X111 are used for connecting peripheral devices with USB connection USB2 0 standa...

Page 17: ...video signal DVI D standard is supported The power delivery is limited to 1000 mA 2 6 8 Additional plug in cards optional There is a type plate on the front cover of the Industrial Server which provi...

Page 18: ...condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours mus...

Page 19: ...the PC must be provided The clearance above and below the housing must be at least 5 cm in order to ensure adequate ventilation of the PC Avoid extreme environmental conditions Attention Extreme envir...

Page 20: ...e you use the provided cable with inlet connector for non heating apparatus to connect the Industrial PC to the power supply Minimum temperature rating of supply cables should be 80 C 3 3 4 Power cord...

Page 21: ...nnections are located at the top side of the Industrial PC and are documented in the Product Description chapter When connecting the cables to the Industrial PC proceed according to the following sequ...

Page 22: ...destroyed Control software typically writes something to the memory drive every few seconds so that the probability of causing damage by switching off while the software is running is very high Switc...

Page 23: ...an alternative type recommended by the manufacturer Notice correct polarity Handling of Lithium Batteries WARNING Lithium Batteries should not be recharged exposed to fire opened and they should be pr...

Page 24: ...Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the ma...

Page 25: ...mensions 6 Assembly dimensions Industrial Server C6670 0010 Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm C66...

Page 26: ...Assembly dimensions Notice mounting orientation Attention The assembly of the unit must take place with the orientation diagrammed here All dimensions in mm 24 C6670 0010...

Page 27: ...istance Sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC compatibility Resistance to interference co...

Page 28: ...KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assista...

Page 29: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this e...

Reviews: