4.6.5
Sine Encoder without data channel (X2)
A sine-cosine encoder without data channel can be used as standard motor feedback.
Select feedback type 7 "SinCos 5V with W&S". Drive executes wake&shake to calculate
the necessary start-up information for the position controller every time the 24V auxiliary
voltage is switched on.
If lead lengths of more than 50m are planned, please consult our customer service.
The thermostat contact in the motor is connected via the encoder cable to X2 and evalua-
ted there.
Frequency limit: 350 kHz
Don't use this feedback type with vertical load (hanging load).