2.9
Technical data
2.9.1
Rated data
max. 230VAC
max. 400VAC
AX25
AX25
Rated data
DIM
03
06
23
26
13
16
23
26
Rated supply voltage
V~
1 x 115V
-10%
to
3 x 230V
+10%
—
3 x 230V
-10%
to
3 x 400V
+10%
—
Max. installed load for S1 operation
(in a multi-axis system)
kVA
7
—
12
—
Rated DC Bus link voltage
V=
160 - 310
310 - 560
Rated output current
(rms value,
±
3%, @ 8kHz)
Arms
3
6*
3
6*
3
6*
3
6*
Peak output current
(max. ca. 5s,
±
3%, @ 8kHz)
Arms
9
12*
9
12*
9
12*
9
12*
Clock frequency of output stage
kHz
8 (can be switched to 16, with power reduction,
please contact our customer support)
Overvoltage switch-off threshold
V
450
—
750
—
maximum load inductance
mH
75
40
75
40
75
40
75
40
minimum load inductance
mH
12
7.5
12
7.5
12
7.5
12
7.5
Form factor of the output current (rated
conditions and min. load inductance)
—
1.01
1.01
Bandwidth of subordinate current
controller
kHz
> 1.2
> 1.2
Residual voltage drop at rated current
V
< 5
< 5
Quiescent dissipation, output stage disabled
W
12
15
12
15
12
15
12
15
Dissipation at rated current
(without regen dissipation)
W
35
60
30
40
35
60
30
40
Inputs/outputs
Analog input, 14-bit resolution
V
±
10
±
10
common-mode voltage max.
V
±
10
±
10
input resistance
k
W
20
20
Digital control inputs
low 0...7 / high 12...36V,
7mA
low 0...7 / high 12...36V,
7mA
Digital control outputs, open emitter
max. 30V, 10mA
max. 30V, 10mA
BTB/RTO output, relay contacts
V
DC max. 30,
AC max 42
—
DC max. 30,
AC max 42
—
mA
500
500
Auxiliary supply, electrically isolated,
without holding brake, without fan
V
20...30
—
20...30
—
A
0.5
0.5
Auxiliary supply, electrically isolated,
with holding brake or fan
(check voltage drop !)
V
24
(-0% +15%)
—
24
(-0% +15%)
—
A
2.5
2.5
Max. output current for holding brake
A
1,5
1,5
Mechanical
Weight
kg
3
1.7
3
1.7
Height, without connectors
mm
230
267*
230
267*
230
267*
230
267*
Width
mm
100
50
100
50
Depth, without connectors
mm
240
240
* with add-on ventilation, see page 72
AX2500 Installation Manual
15
Beckhoff
02/06
Technical description
Summary of Contents for AX2500 Series
Page 31: ...3 4 4 Connector assignments AX2500 Installation Manual 31 Beckhoff 02 06 Installation...
Page 65: ...5 3 2 3 Status display on the master AX2500 Installation Manual 65 Beckhoff 02 06 Setup...
Page 68: ...This page has been deliberately left blank 68 AX2500 Installation Manual Setup 02 06 Beckhoff...