Easco Boiler
SM5
Series Boiler
Boiler
Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate
Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange
Insertion
20
CF800
BCF403
CF100KH
5.80
4.50x45P
3
10
3
150
N/A
51628
5.00"
25
CF1000
BCF101
CF102KD
7.30
4.00x45P
4
20
N/A
300
N/A
51629
5.00"
30
CF1400
BCF205
CF102KE
8.70
5.00x45P
7
20
40
150
300
51629
5.00"
35
CF1400
BCF205
CF102KE
10.20
5.50x45P
9
30
70
150
300
51629
5.00"
40
CF2300A
BCF304
CF102KG
11.70
7.00x45P
0
16
30
150
275
51630
5.00"
50
CF2300A
BCF304
CF102KG
14.60
8.50x45P
3
20
40
150
275
51630
5.00"
60
CF2300A
BCF304
CF102KG
17.50
10.00x45P
6
20
70
150
300
51630
5.00"
60S
CF2300A
BCF304
CF102KG
17.50
10.00x45P
6
20
70
150
300
51630
5.00"
70
CF2500
BCF1801
CF102KP
20.40
6.00x45P (2)
8
40
90
275
275
51630
5.00"
80
CF3500
BCF1301
CF80KM
23.30
6.50x45P (2)
7
30
80
300
300
51630
5.00"
90
CF3500
BCF1301
CF114KR
26.20
7.50x45P (2) 7-1/2
40
90
300
300
51631
5.00"
100
CF3500
BCF1301
CF114KR
29.20
8.50x45P (2)
8
50
100
280
280
51631
5.00"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Flange requires an additional adapter plate.
Page 17
Summary of Contents for BRYAN STEAM CF2300A
Page 35: ......