33
DE
GB
FR
NL
Indicator LED’s
Basic control S55
ELS Professional Card
LED
Illustration
Indication
Meaning
POWER
+UB
on
Power.supply.connected
off
No.power.supply.connected
UP
AUF
on
Door.moves.UP
DOWN
ZU
on
Door.moves.DOWN
LED
Indication
Meaning
Pilot
on
Normal.mode
1.flashes
Setting.mode.step.1:.Move.to.bottom.end.limit.-.dead-man.mode
.flashes
Setting.mode.step.:.Move.to.top.end.limit.-.jogging.mode
3.flashes
Setting.mode.step.3:.Move.to.top.end.limit.-.dead-man.mode
4.flashes
Setting.mode.step.4:.Move.to.top.end.limit.-.jogging.mode
5.flashes
Setting.mode.step.5:.Move.door.to.VES.gauge.(35.mm).-.automatic.mode
6.flashes
Setting.mode.step.6:.Move.to.bottom.end.limit.-.dead-man.mode
7.flashes
Setting.mode,.partial.opening:.Move.to.partial.opening.position.-.dead-man.mode
contin..flash.
slow.(0.5.Hz)
Reference.run.to.determine.current.door.position..The.control.unit.only.allows.the.door.to.
move.towards.the.reference.points.
contin..flash.
fast.(5.Hz)
Programming.button.is.pressed..However,.it.is.not.possible.to.move.to.setting.mode.or.to.
the.next.programming.step.
off
No.end.limits.programmed.(Fault.LED.illuminated).-.dead-man.mode
Fault1
on
Stop.button.pressed;.wicket.door.switch/spring.break.safety.device.actuated.triggered;.
Defect.on.card.(no.redundant.safety);
Setting.mode:.Top.end.limit
1.flashes
Reference.value.encoder.of.drive.faulty;.duration.overrun
.flashes
Blocking.of.the.door.drive;.incremental.encoder.of.drive.faulty
3.flashes
No.switch.pulse.from.the.safety.edge.at.the.bottom.end.limit
4.flashes
A.further.automatic.adjustment.of.the.bottom.shut-off.point.is.not.possible.
contin..flash.
slow.(0.5.Hz)
Fault.in.computer.system.(mains.voltage.reset)
Fault2
on
No.end.limits.programmed;.setting.mode:.Bottom.end.limit
1.flashes
Safety.circuit.of.drive.has.been.triggered
.flashes
Safety.edge.actuated.just.before.downward.movement.of.door.or.internal.safety.edge.
sensor.faulty
3.flashes
Slack.rope/pull.in.safety.activated
4.flashes
Fault.in.monitoring.computer.(mains.voltage.reset)
5.flashes
The.door.encountered.an.obstacle.five.times.during.automatic.closing
6.flashes
The.unit.connected.to.system.socket.X1.is.faulty
contin..flash.
slow.(0.5.Hz)
Photoelectric.barrier.actuated
USA/
SKS
on
Safety.edge.actuated
off
Safety.edge.not.actuated
Sonder
off
DIP.switch.released/control.times.unchanged
1.flashes
DIP.switch.inhibited/control.times.unchanged
.flashes
DIP.switch.released/control.times.changed
on
DIP.switch.inhibited/control.times.changed