Operating Instructions
Overview of control times
time
duration
Description
Z0
0.5.s
stop.time.in.counter.command.UP.by.button.UP.or.light.barrier
Z1
.s
Free.time.during.freeing.of.obstructions
Z
0.3.s
Stop.time.during.counter.command.UP.by.safety.edge
Z3
3.s
early.warning.time
Z4
.-.40.s
Time.for.automatic.closing.with.integrated.time.module
Z5
0.1.s
‘reversing.time.to.support.the.safety.edge
Z6
10.s
Yard.light.On.duration
Z7
is.programmed.automatically
Z8
1.s
Waiting.time.for.safety.edge.signal.in.lower.stop.position
Z9
0.1.s
Blocking.detection.time
Z10
0.05.s
Jogging.mode.for.end.limit.setting
Troubleshooting ?
Caution
Fault elimination must only be performed by an authorised electrician.
Note
Also check for faults via LED on the circuit board of the base control and the ELS Professional Card.
Fault
Possible cause and rectification
No.reaction.when.pressing.buttons
LED.
+UB/power
.does.not.illuminate
•. Check.supply.voltage.(terminals.
L3/L2/L1/N
.(NETZ)).
•. Check.fine-fuse.
F1
.(400.mA.T).
•. Check. E-STOP. button. circuit). (terminals.
1/2
..
(EMERGENCY-STOP)).
No.reaction.when.pressing.buttons
LED.
+UB/power
.illuminates
•. Check.safety.circuit.of.drive.(crank.(chain),.drive.temper-
ature,
.
safety.limit.switch.(
S1F/S2F
,.yellow.cam)).
•. Check.terminals.
3/6
.(STOP),.
9/10
.(LS),.and.
14/15
.(slack.
rope)..If.these.terminals.are.not.occupied,.they.must.be.
bridged.
•. Check.whether.you.are.using.a.suitable.control.card.for.
the. drive.. MLS. Basic. Card/MLS. Professional. Card. for.
drive. with. mechanical. limit. switching,. ELS. Professional.
Card.for.drive.with.electronic.limit.switching(BES)
Model
S55 with ELS Professional Card
Power.supply
3N~.30/400.V.50/60.Hz
Motor.rating
max..1.8.kW
Control.voltage
4.V.DC,.not.stabilised
Control.power
max..15.mA
Housing.dimensions
18.x.180.x.90.mm.(W.x.H.x.D)
Weight
ca..1.5.kg.(w/o.connector.cable)
Protection.type
IP54.,.only.for.assembly.inside
Ambient.temperature.range
0.°C.....+50.°C
Fused.hook-up.connection
3.x.10.A
Technical Data