3
Operating Instructions
Setting the DIP switches
ELS Professional Card
Switch
Position
Illustration
Function
DIP 1.1
ON
1
2 3 4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Pneumatic.safety.edge.connected,
DW.testing.is.active
OFF
1
2 3 4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Electric.or.FRABA.OSE.safety.edge.connected
DIP 1.2
ON
1
2
3 4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Deactivate. at. the. bottom. end. limit. via. switching. pulse. from. the. electric,.
pneumatic.or.optoelectronic.safety.edge
OFF
1
2
3 4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Deactivate.at.the.bottom.end.limit.via.the.cam.limit.switches.on.the.drive
DIP 1.3
ON
1 2
3
4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Move.up.to.the.top.end.limit.after.a.safety.stop
OFF
1 2
3
4 5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Move.clear.of.the.obstacle.after.a.safety.stop.with.a.clearance.time.
Z1
.=.
.s
DIP 1.4
ON
1 2 3
4
5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relieve.the.safety.edge.at.the.bottom.end.limit.(reversing).with.reversing.
time.
Z5
.=.100ms
OFF
1 2 3
4
5 6 7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
No.relief.(reversing).at.the.bottom.end.limit
DIP
1.5/1.6
ON/ON
1 2 3 4
5 6
7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.Warning.light,.early.warning.
only.for.automatic.closing.Closing
Relay.:.Yard.light
ON/OFF
1 2 3 4
5 6
7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.traffic.lights,
door.at.top.end.limit
Relay.:.Yard.light
OFF/ON
1 2 3 4
5 6
7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.warning.light,
always.with.early.warning
Relay.:.Yard.light
OFF/OFF
1 2 3 4
5 6
7 8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.door.status,
door.at.top.end.limit
Relay.:.door.status,
door.at.bottom.end.limit
DIP 1.7
ON
1 2 3 4 5 6
7
8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.warning.light.flashing,.flash.
rate.1.Hz
Relay.:.yard.light,
control.pulse.1.s
OFF
1 2 3 4 5 6
7
8
ON
DIP
1 2
ON
DIP 1
DIP 2
Relay.1:.warning.light,
on.continuously
Relay.:.yard.light,
for.10.s.(time.
Z6
)
DIP 1.8
ON
1 2 3 4 5 6 7
8
ON
DIP
1 2
ON
DIP 1
DIP 2
Automatic.closing.time.
Z4
.is.reduced.to.3.s.after.releasing.the.photoelec-
tric.barrier
OFF
1 2 3 4 5 6 7
8
ON
DIP
1 2
ON
DIP 1
DIP 2
Automatic.closing.time.(time.
Z4
).re-runs.via.light.barrier.function.
DIP 2.1
ON
1 2 3 4 5 6 7 8
ON
DIP
1
2
ON
DIP 1
DIP 2
Electric.or.pneumatic.safety.edge.connected
OFF
1 2 3 4 5 6 7 8
ON
DIP
1
2
ON
DIP 1
DIP 2
Optoelectronic.safety.edge.FRABA.OSE.connected
DIP 2.2
ON
1 2 3 4 5 6 7 8
ON
DIP
1
2
ON
DIP 1
DIP 2
Terminating.resistance.of.safety.edge.=.1..kOhm
OFF
1 2 3 4 5 6 7 8
ON
DIP
1
2
ON
DIP 1
DIP 2
Terminating.resistance.of.safety.edge.=.8..kOhm