Becker Avionics
General Description
Restriction for Use
DV17551.03 Issue 03 June 2020
RCU6512
17
1.6 Safety-Conscious Utilization
The device(s) may be installed on an aircraft only by an approved aeronautical
company (e.g. Part 145) which shall also examine the installation.
•
The installation of the device into an aircraft may be carried out only by an
authorized installation company. The country regulations always have to be
obeyed.
•
Use the product only in the specified conditions, see "Technical Data",
page 18.
•
Power supply:
o
Do not connect the device to AC sources.
o
Make sure that the device is connected to the mandatory DC source, see
"Technical Data", page 18.
o
Do not connect the device with reversed polarity to the DC source.
•
Circuit breaker:
o
Use the applicable fuses in the power supply line for protection of the
application, see "Technical Data", page 18.
Cleaning:
•
Do not use aggressive cleaning agents e.g. Acetone.
o
These cleaning agents can cause damages.
Excessive pulses on the DC bus of the aircraft may cause damage on electrical
circuits of any installed instrument.
Do not power-on the device during engine start or shutdown.
1.7 Restriction for Use
The product is to be used inside the declared limits.