Crushing or shearing points must be avoided or protected.

When installing the drive, all-pole disconnection from the mains with a contact gap of at least 3 mm per pole

must be provided (EN 60335).

If the drive mains connecting cable is damaged, it must be replaced with the same type of mains connecting

cable, which is available from the drive manufacturer.

Attention

Safety instructions for avoiding property damage.

Ensure that there is adequate clearance between moving parts and adjacent objects.

The drive must not be carried by the mains connecting cable.

All latching connections and fastening screws on the brackets must be checked to ensure that they are se-

cure.

Ensure that nothing rubs against the tubular drive, such as shading solution attachments, screws, etc.

Intended use

The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This type of tubular
drive is compatible with the B-Tronic control program and suitable control units with bidirectional KNX radio.
This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g.,
Zurfluh-Feller, Simu, GAH Alberts and Deprat). These are detected automatically.
If the springs or the top lath are screwed or riveted to the barrel, a point must be set in the lower limit position.
For sun protection applications, please use only the types of tubular drive designed for this purpose.
This type of tubular drive is designed for use in single systems (one drive per barrel).
The tubular drive must not be used in potentially explosive areas.
The connecting cable is not suitable for transporting the drive. Always carry the drive by the housing tube.
Other applications, uses and modifications are not permitted in order to protect the safety of the users and others, since these ac-
tions can impair the system’s safety and carry the risk of personal injury and property damage. The drive manufacturer does not
accept liability for damages or injury arising from such actions.
Always observe the information in these instructions when operating or repairing the system. The drive manufacturer does not ac-
cept liability for damage or injury resulting from improper usage.

Attention

Only use anti-lifting devices if the roller shutter laths are sufficiently strong. The closed curtain must not pro-

ject beyond the guide tracks or else there is a risk of the joint between the top two laths being subjected to ex-

cessive strain and getting damaged.

5

Summary of Contents for P5-B01

Page 1: ...r drive with integrated radio transceiver Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Page 2: ...Undoing the mounting pin 9 Drive adapter for obstacle detection 9 Assembling the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 10 Fixing the drive adapter to the barrel dia 35 and dia 45 10 Mounting the drive in the tube 10 Preparation for Commissioning 11 Checking that the running direction is cor...

Page 3: ... Anti freeze mechanism in the upper limit position can be enabled Considerably lower stop load and thus considerably lower shading solution load Smooth operation of the system and the drive increases the service life For plug in connecting cable Fly screen protection function Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture ...

Page 4: ...ied with All work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists in particular qualified electricians Only use spare parts tools and accessory devices which have been approved by the drive manufacturer Unapproved third party products or modifications to the system and its accessories represent a risk t...

Page 5: ... e g Zurfluh Feller Simu GAH Alberts and Deprat These are detected automatically If the springs or the top lath are screwed or riveted to the barrel a point must be set in the lower limit position For sun protection applications please use only the types of tubular drive designed for this purpose This type of tubular drive is designed for use in single systems one drive per barrel The tubular driv...

Page 6: ...e dead connecting cable into the drive head until the locating lug clicks into place in the drive If necessary use a suitable flathead screwdriver to assist with insertion Set the screwdriver into one of the two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug 6 ...

Page 7: ...the connecting cable must be disconnected On drives with a diameter Ø35 insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver Ø35 A A snap in pin 7 ...

Page 8: ... drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a qualified electrician Prior to assembly the power supply must be disconnected and secured Please give the enclosed connection information to the responsible elec trical contractor These drives cannot be operated with conventional switching elements switches timers and the like If you want ...

Page 9: ...he tab washer 1 upwards and pull out the mounting pin 2 Drive adapter for obstacle detection If you wish to use the obstacle detection function you must use the drive adapter for obstacle detection Assembling the drive adapter with drive adapter safety catch Put the drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inse...

Page 10: ...tube or drop it into the barrel The curtain can only be secured using springs or anti lifting devices Mounting the drive in the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These groove recesses have different sizes and allow the drive to fit exactly For rou...

Page 11: ...tracks When first installing using springs and adjusting the limit position to lower stop the barrel in the lower limit position turns approx 1 4 of a turn further than usual In doing so the tubular drive is able to detect the use of anti lifting devices or springs automatically The tubular drive switches off automatically Limit position status indicator A brief stopping and restarting indicates t...

Page 12: ...the appropriate description in the instructions for the B Tronic transmit ter Checking that the running direction is correct It is only possible to change the direction of rotation if no limit position has been set Press the UP or DOWN button The shading solution runs in the desired direction Direction switch is OK If the shading solution runs in the wrong direction the running direction must be s...

Page 13: ... ring Use of the drive s obstacle detection system as personal protection is not permitted It has been designed ex clusively to protect the roller shutters or sun protection system from being damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos ite direction The following are detected In the DOWN direction ...

Page 14: ... Emission sound pressure level dB A 70 Technical data dia 45 Model R8 B01 R12 B01 R20 B01 R30 B01 R40 B01 Type R8 17C PROF KNX R12 17C PROF KNX R20 17C PROF KNX R30 17C PROF KNX R40 17C PROF KNX Rated torque Nm 8 12 20 30 40 Output speed rpm 17 17 17 17 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 5 0 75 ...

Page 15: ...ion Tubular drive has detected an increase in load Briefly run the curtain in the opposite dir ection then continue in the desired direc tion Tubular drive is overloaded Use a higher torque tubular drive Tubular drive does not operate at the set switching time Tubular drive is in manual mode Use a B Tronic transmitter to switch the tubular drive into automatic mode Set switching times change Frequ...

Page 16: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 16 ...