Limit position settings and configurations
The commissioning (e.g. setting the limit positions etc.) and later configurations are only possible with a B-Tronic transmitter.
Please find the appropriate description in the instructions for the B-Tronic transmitter.
Attention
When operating the tubular drive without the drive adapter for obstacle detection, if using springs a point must
be set in the lower limit position.
Possible limit position settings
•
Upper stop to lower stop
•
Upper point to lower point
•
Upper stop to lower point
•
Upper point to lower stop
The limit position becomes fixed after the tubular drive has turned off
automatically
in the desired position three times.
Possible configurations
•
Intermediate positions I+II
•
Memory function
•
Upper anti-freeze mechanism
•
Fly screen protection function
•
Repeater mode
Obstacle detection
Caution
Obstacle detection is only active in conjunction with the “drive adapter for obstacle detection”.
In addition, please note that the drive must be pushed in to the shaft as far as the band of the thrust ring.
Use of the drive’s obstacle detection system as personal protection is not permitted. It has been designed ex-
clusively to protect the roller shutters or sun protection system from being damaged.
If the drive is correctly installed, it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos-
ite direction.
The following are detected:
In the DOWN direction
•
A curtain jam when closing due to objects on the window sill or sticking of the lateral guide tracks.
In the UP direction
•
Extremely large increase in the load (e.g., ice on the end strip)
To ensure that the roller shutter curtain safely enters the guide tracks, obstacle detection is inactive for approx. 1.5 revolutions of
the barrel from the upper limit position.
To ensure complete closing of the roller shutter curtain at the lower limit position, the curtain does not reverse once it gets to ap-
prox. 260° (dia. 35) and 210° (dia. 45) from the lower limit position.
Disposal
This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc-
ling or disposal for this product in your country.
The packaging material must be disposed of properly.
Maintenance
These drives are maintenance-free.