Setting the limit positions using the programming unit
Intelligent installation management
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com-
plete.
These tubular drives are designed for short-time operation (for the operating mode,
please see technical data).
The number of cycles an awning is capable of depends on the barrel diameter and awning
extension.
The drive running time is cut short if the drive has not cooled down fully after the previous
use.
Programming button
Travel button
Retract
Extend
Extended point to retracted stop
Press the travel button on the programming unit to move the sun protection system to
the desired Extend limit position. This must be at least 2 revolutions of the barrel away
from the retracted limit position. Next, release the travel button for a moment to cut
the power to the tubular drive.
Press the programming button for 3 seconds to save this position. The tubular drive
clicks to confirm storage of the maximum projection position. You can now release
the programming button; the position is now saved.
Use the travel button to retract the sun protection system,
without pausing
, until the
tubular drive switches itself off.
The drive saves the limit position “Stop” permanently once it has been reached 3
times in succession. Installation is then complete. As a final check, run the sun pro-
tection system to the two limit positions again.
To ensure that the limit position is reliably detected and the sun protection system is
fully closed, the tubular drive pulls the cloth slightly more strongly during the installa-
tion.
On subsequent runs, the tubular drive automatically carries out a short reversal to un-
tension the cloth in the retracted limit position.