Adjusting the limit positions with a rotary switch or a locking button
Intelligent installation management
Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit position "Stop"
The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com-
plete.
If the tubular drive switches off prematurely while extending/retracting, due to an obstruc-
tion, the obstruction can be cleared by extending/retracting the screen and removing the
obstruction. The upper limit position can be set by extending/retracting again.
Extended point to retracted stop
Open to the desired extended limit position.
Carry out the following sequence without interruption between the individual drive commands.
▻
The tubular drive makes a "click" sound to confirm.
1 s
1 s
until STOP and hold until
Then retract to the permanent upper stop. During travel, the end position status in-
dicator (ESI) must be displayed before the end position is reached.
▻
The tubular drive switches off automatically.
The limit positions are now set.
Deleting the limit positions with a rotary switch or a locking button
The switching commands sequence must be carried out in quick succession. Any addi-
tional functions that have been set are retained.
Carry out the following deletion sequence without interruption between the individual drive commands:
STOP
1 s
until
1 s
1 s
1 s
1 s
1 s
1 s
The tubular drive confirms.
Both limit positions are deleted.
11