![Becker B-Tronic EasyControl EC5401B Assembly And Operating Instructions Manual Download Page 30](http://html1.mh-extra.com/html/becker/b-tronic-easycontrol-ec5401b/b-tronic-easycontrol-ec5401b_assembly-and-operating-instructions-manual_2718698030.webp)
Clean-up function for B-Tronic products
All receivers that are programmed and no longer present can be cleared with
the clean-up function.
The clean-up function is always applied to the selected chan-
nel. The switching commands sequence must be carried out
in quick succession. B-Tronic products that were temporarily
unreachable during the process should be reprogrammed.
Select the desired channel.
Put the transmitter into master mode.
1 second
Press the programming button for 1 second.
1 second
Press the programming button again for 1
second.
6 seconds
Press the programming button again for 6
seconds.
The LED flashes yellow quickly for about 3
seconds, then changes to green.
Now press the changeover button to leave
master mode.
30