![Becken BKGH4446 Instruction Manual Download Page 28](http://html1.mh-extra.com/html/becken/bkgh4446/bkgh4446_instruction-manual_2718221028.webp)
28
3. The correct adjustment is obtained when
the flame has a length of about 3-4 mm.
- For butane/ propane gas, the adjusting
screw must be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go
out by quickly turning from maximum
flow to minimum flow. If it does, then
remove the control knob and make
further adjustments to the gas flow,
testing it again once the adjustment has
been made.
4. Repeat this process for each one of the
gas taps.
Adjustment screw
• Do not dismantle the tap shaft: in the event of a
malfunction, change the whole tap.
• Before placing the burners back on the top place, make
sure the injector is not blocked.
• A full operational test and a test for possible leakages must
be carried out after the gas conversion (using soap water
or a gas detector).
• After completing conversion, a qualified technician or
installer has to mark “V” on the right gas category to
match with the setting in rating plate. Remove the previous
setting “V” mark.