www.beast-tek.com
Dirty Glitch Assembly Manual
| 10
Step 9
Time for some testing! Double check all solder joints. When you are happy with your work, connect the
power cable to a eurorack power supply so that test measurements can be made with a multimeter.
IMPORTANT:
Do NOT do this in a case with other modules installed
. If there is a fault with your work, it
could fry/burn/destroy other modules connected to the same power system.
Using a multimeter set to DC volts with a range capable of measuring 5v – 24v, test the voltages at the
following points:
IC2 – connect the positive probe to pin 4 and the negative probe to pin 11.
You should get a reading of between 23v to 24v .. the power diodes used to protect the module against
reverse power connection do cause a small voltage drop of approx. 0.4v
In the photo below, my reading is 22.8v because I am using a 4ft power cable (which causes significant
voltage drop) so that I can assemble and take photos easily.