5
REMOTE CONTROL
To control the Moving Head easily via the supplied remote control, you must aim the remote
at the front of the fixture and be no more than 30 feet away.
STAND BY
- Press this button to activate the Moving head.
FULL ON
- Press this button to switch on the LED illumination.
You must hold the button,
then all LEDs will go on.
GOBO
– No functionb
Sou/Tilt –
By means this button allows you to switch between fast and slow pan / tilt
movements.
"" and "DIMMER -"
– Press this button to adjust the brightness level.
STROBE
- Press this button to activate the strobe function.
You have 2 strobe effects. Short
press functions as a flash function. If you want a strobe, you'll need to hold the button.
COLOR
- Press this button to select the individual colour via 1-9 buttons. (1 Red; 2Green; 3
Blue; 4 White, 5 Yellow, 6 Magenta, 7 Cyan, 8 Pink, 9 White all colours on). Adjust the
brightness level via “” and “DIMMER -“.
SOUND ON & OFF
- These buttons activate and deactivate the sound active mode.
SHOW
- Press this button to active the show mode. Use the 1-4 buttons to select your
desired built-in programs.
To control the Moving Head easily via the supplied remote control, you must aim the remote at the front of the fixture and be no
more than 30 feet away.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit’s optics.
Make sure the area below the installation place is free from unwanted persons during servicing
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION:
We strongly recommend internal cleaning to be carried out by qualified worker!