background image

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comment:  Press MENU to back to the last option. Press ENTER to save. 

How to erase password:  

Please press MENU→UP/ DOWN→MENU SYS-SET→ENTER→UP/ DOWN→SYS-SET 
Password→ENTER→UP/ DOWN→NO→ENTER→password(default 680)→ENTER. 

 

 

 

 

 

 

 

 

M-Test  AUTO-5 

ENTER→Auto-5 

M-Test  AUTO-6 

ENTER→Auto-6 

M-Test  AUTO-7 

ENTER→Auto-7 

M-Test  AUTO-8 

ENTER→Auto-8 

M-Test  ALL 

ENTER→Auto-1 to Auto-8 

M-Test MOT-Off 

ENTER→Auto Off 

MENU 

SYS- 
SET 

 

 

ENTER 

↓ 

UP/DOW

SYS-SET 

DMX-OUT 

ENTER→UP/DOWN to select 
YES/NO→ENTER.  

In Master-Slave model, YES stands for 
Master fixture turns ON signal output; NO 
stands for Master fixture turns OFF signal 
output. 

SYS-SET 

PAN-R 

ENTER→UP/DOWN to select 
YES/NO→ENTER. YES stands for X axle 
rotates counter-clock-wise, NO stands for X 
axle rotates clock- wise. 

 

 

MENU 

SYS- 
SET 

 

Press  

ENTER↓ 

UP/DOW

SYS-SET 

Tilt-R 

ENTER→UP/DOWN to select 
YES/NO→ENTER. YES stands for Y axle 
rotates counter-clock-wise, NO stands for Y 
axle rotates clock- wise.  

SYS-SET 

RST-SYS 

ENTER→UP/DOWN to select 
YES/NO→ENTER. YES stands for RESET. 
NO stands for current status. 

SYS-SET 

Password 

Press 
ENTER↓ 

UP/DOW

YES to set up three-digit-
number password. 
ENTER→UP/DOWN to choose 
digit(0-

9)→ENTER. Default 

password is 680. Power off 
fixture to active password lock 
function. 

NO to unlock password. 
ENTER→

UP/DOWN to key in 

password→ENTER. Default 
password is 680. 

MENU 
RESET 

→ENTER   

 

 

Summary of Contents for 150.529

Page 1: ...MHL 373 Wash 37x3W RGB 14Ch DMX Ref nr 150 529 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES V1 ...

Page 2: ...truss system with clamps Make sure nobody stands in the mounting area Mount the effect at least 50cm away from inflammable material and leave at least 1 meter space on every side to ensure sufficient cooling This unit contains high intensity LEDs Do not look into the LED light to prevent damage to your eyes Do not repeatedly switch the fixture on and off This shortens the life time Keep the unit o...

Page 3: ...ij gebruik en direct na gebruik Om ongevallen in bedrijven te voorkomen moet rekening worden gehouden met de daarvoor geldende richtlijnen en moeten de aanwijzingen waarschuwingen worden gevolgd Zorg voor een extra veiligheidsketting als het apparaat op hoogte wordt gehangen Gebruik een truss systeem met clamps Ga nooit onder het apparaat staan bij ophanging Monteer minimaal 50 cm van brandbare ob...

Page 4: ...en system mit Haken Während der Montage darf sich niemand im Bereich darunter aufhalten Das Gerät muss mindestens 50cm von brennbaren Materialien entfernt angebracht werden Lassen Sie einen Mindestabstand von 1m an jeder Seite des Geräts frei um ausreichende Kühlung zu gewährleisten Das Gerät besitzt eine hochintensive LED Niemals direkt in die LED blicken um die Augen nicht zu beschädigen Niemals...

Page 5: ...s Desconéctelo si no lo va a usar Si el aparato no se ha usado en mucho tiempo puede producirse condensación Deje el aparato a temperatura ambiente antes de encenderlo Nunca utilice el aparato en ambientes húmedos o en el exterior Durante el funcionamiento la carcasa se calienta muchísimo No la toque durante el funcionamiento o inmediatamente después Para prevenir accidentes en las empresas debe s...

Page 6: ...e installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails Make su...

Page 7: ... the installation place is free from unwanted persons during servicing Housings fixations and installations spots ceiling truss suspensions should be totally free from any deformation The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order to protect the fixture from overheat the cooling fans if any and ventilation openings...

Page 8: ...UNC Jump ENTER run stand alone LED FUNC Flash ENTER run stand alone LED FUNC LED Auto ENTER run stand alone Gradual Jump Flash Built in macro LED FUNC Sound ENTER Sound active LED FUNC LED SP ENTER UP DOWN to speed adjust 0 255 from t fast to slow ENTER LED FUNC FUN Off ENTER LED Function Off MENU M Test ENTER UP DOWN M Test AUTO 1 ENTER Auto 1 M Test AUTO 2 ENTER Auto 2 M Test AUTO 3 ENTER Auto 3...

Page 9: ...aster fixture turns OFF signal output SYS SET PAN R ENTER UP DOWN to select YES NO ENTER YES stands for X axle rotates counter clock wise NO stands for X axle rotates clock wise MENU SYS SET Press ENTER UP DOW N SYS SET Tilt R ENTER UP DOWN to select YES NO ENTER YES stands for Y axle rotates counter clock wise NO stands for Y axle rotates clock wise SYS SET RST SYS ENTER UP DOWN to select YES NO ...

Page 10: ...sh to connect a DMX controller with other XLR outputs you will need to use adapter cables Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain Always connect the output of one unit with the input of the next unit until all units are connected If you use a controller with 5 pin DMX connection you will need to use a 5 pin to 3 pin adapter Caution a...

Page 11: ...ess setting on fixture and controller Bad data link connection Inspect cables and correct poor connections and or broken cables Conflict between tracking and vector control Eliminate scene cross fade on controller Data link not terminated Insert termination plug in output of last fixture Defective fixture or 2 devices transmitting on link Bypass fixtures one at a time until normal operation is reg...

Page 12: ...etherlands Product number 150 529 Product Description MHL 373 Wash 37x3W RGB 14Ch DMX Regulatory Requirement EN 60598 1 2 17 2009 EN 55015 2007 EN 61547 2009 EN 61000 3 2 3 3 The product meets the requirements stated in Directives 2006 95 and 2004 108 EC and conforms to the above mentioned Declarations Almelo 28 09 2014 Signature ...