background image

EDC Rotary™ Flashlight User’s Guide 

 

Copyright 2019 by HDS Systems, Inc. 

All rights reserved. 

 

Basic Operation 

Clicking  the  button  (a  quick  press  and  release  of  the  button) 
will turn on your flashlight.  Clicking the button a second time will 
turn off your flashlight. 

While your flashlight is on, you can press-and-hold the button 
to momentarily activate Maximum – releasing the button returns 
to  the  previous  brightness  level.    You  can  also  click-press-
hold-release  to  activate  Maximum  and  stay  on  Maximum.  
There is no delay between the click and the press. 

You  can  select  the  Maximum  setting  directly  from  off  by 
performing  a  click-press-hold-release.    There  is  no  delay 
between the click and the press. 

Your light turns on to the brightness level selected by the rotary 
control. 

Rotary

Adjustable

Brightness

Level

 

 

Use  the  rotary  control  to  select  any  brightness  level  between 
0.02 lumens and Maximum. 

The  Brightness  menu  may  be  used  to  enable  two  additional 
presets accessible through double-click and triple-click. 

Low Battery Indication 

Your  flashlight  will  turn  off  momentarily  and  then  back  on  one 
level  below  the  previous  brightness  level  when  the  battery  is 
unable  to  supply  enough  power  to  run  the  current  brightness 
level.    This  process  is  repeated  as  needed  as  the  battery’s 
power is depleted. 

Your  flashlight  will  double-blink  once  every  two  minutes  to 
remind  you  that  the  battery  needs  to  be  changed  when  the 
battery  is  no  longer  capable  of  maintaining  a  50  lumen  output 
level  and  you  are  asking  for  an  output  level  higher  than  the 
battery can maintain. 

Your flashlight restricts the output to the highest brightness level 
the battery can maintain.  However, if you turn off your flashlight 
and  turn  it  back  on  again  to  a  higher  level,  your  flashlight  will 
slowly  step  up  through  the  brightness  levels  testing  the  battery 
again. 

Button Lockout 

You  can  disable  the  switch  by  unscrewing  the  battery 
compartment  from  the  head  one  half  turn.    The  O-ring  will 
remain completely covered.  You restore operation of the switch 
by screwing the battery compartment completely into the head. 

You can also enable the Button Lockout option.  When enabled, 
triple-click from off locks and unlocks the button. 

Reviews: