Locate the two low-voltage wires near the main 
pipe. Remove the insulation from the low-volt 
wire. Insert the low-volt wire into the spring-
loaded low-volt connectors (refer to figure 3). 

Be certain you comply with your local electrical 
codes and regulations. 

The power cable has a three prong style 
connector on one end. This connector must be 
plugged into the matching connector on the 
power unit. Plug the other end of the power 
cable into the wall electrical outlet.

You are now ready to check the installation of 
the unit:

Plug the hose into each inlet valve to 

• 

be sure the electrical contacts operate 
properly.
Check the inlet valve for air leaks.

• 

Check each pipe connection for air leaks.

• 

Be sure the dirt receptacle is properly 

• 

secured to the power unit.
Be sure the filter is properly installed in the 

• 

power unit.

Your cleaning system is ready to use.

Your central vacuum 
system starts and 
stops automatically. 
To turn the system on, 
plug the hose into a 
wall inlet valve. To turn 
it off, remove the hose 
from the valve (refer to 
figure 4).

Electrical Fault Protection

The central vacuum system employs features 
that monitor the following operating levels: 
AC voltage, current draw and circuit board 
temperature. If the voltage is below or above 
standard operating voltage, high current 
draw or locked rotor, the power unit will not 
operate. In this case the LED next to the On/
Off button will blink or go out until the problem 
ceases. In the event any one of these problems 
happening, make sure all low-volt switches 
are in the OFF position, then press the on/off 
button, unplug hose, or wait for temperature 
to lower. If problems persist, contact the 
authorized service center nearest you.

In the case of power failure, the power unit 
will return to its previous state when power 
returns. For example, if a hose is plugged in 
with the hose switch on, or a straight air hose 
is plugged into a wall valve, then the power unit 
will turn back on. If the power unit was turned 
on at the unit prior to power loss then the unit 
will not turn back on.

Inlet valves

Plugging the hose into an inlet valve complete 
a low-voltage electrical circuit which activates 
a relay and turns on the power unit. To turn off 
the power unit, unplug the hose from the inlet. 
When unplugging the hose, hold the inlet cover 
open for a few seconds to allow suction to 
decrease and protect the inner seal. 

An obstruction in the inlet valve may cause the 
power unit to continue to run after the hose 
has been removed from the inlet. To shut down 

Figure 3

HOW TO USE

Figure 4

Summary of Contents for Platinum SC335

Page 1: ...PLATINUM OWNER S MANUAL ...

Page 2: ...M Platinum Operating Maintenance Instruction Manual CONTENTS Introduction 3 How To Use 7 Important Safeguards 4 Maintenance 9 Grounding Instructions 5 Troubleshooting 10 Installation 6 Service Information 11 ...

Page 3: ...ymptoms To obtain the maximum benefit from your BEAM System please read this manual carefully prior to use Then enjoy cleaner healthier living and years of trouble free performance For more information on BEAM Central Vacuum Systems and other innovative BEAM products visit www beam com Components of a BEAM Central Vacuum System Power Unit Dust Collection Receptacle Mounted in the utility room base...

Page 4: ...by or near children r This appliance is not intended for use by persons including children with reduced physical r sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Use only as described in this manual Use only manufacturer s recommended attachments r Do ...

Page 5: ...o not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician WARNING r If the supply cord is damaged it must be replaced by a special cord available from your local authorized dealer distributor Grounded Outlet Grounding Pin Grounded Pin Receptacle GENERAL INFORMATION The central vacuum system is designed for dry pick up ...

Page 6: ...ation would be in a garage where you could vacuum your car or garage area and where emptying the dirt receptacle and cleaning the filter would be more convenient Other suitable locations are in the basement laundry room or ventilation storage room Install Power Unit You are now ready to install the power unit Be sure the power unit will be located at least 30cm from the ceiling and any adjacent wa...

Page 7: ...e current draw and circuit board temperature If the voltage is below or above standard operating voltage high current draw or locked rotor the power unit will not operate In this case the LED next to the On Off button will blink or go out until the problem ceases In the event any one of these problems happening make sure all low volt switches are in the OFF position then press the on off button un...

Page 8: ...ols allowing you to clean virtually any surface from floor to ceiling The tools can be used with the wand or directly on the hose handle The combo tool is used for all around floor and general cleaning and is used about 80 of the time It allows you to move from carpets to hard floor surfaces without stopping by switching the convenient toe switch on top of the tool The round dusting brush makes du...

Page 9: ...e contents Return the receptacle and turn it to the right refer to figure 6 To avoid suction leakage make sure the receptacle is securely attached Filter maintenance BEAM s exclusive filter is permanent and self cleaning However if cleaning is desired follow the steps listed below NOTE Do not operate this unit without the filter in place CAUTION Disconnect power cord from electrical outlet before ...

Page 10: ...he inlet and push the obstruction through Or with another vacuum you can reverse the suction in the system to remove the clog If neither method is successful call your BEAM dealer distributor Have your authorized BEAM dealer 3 distributor check the gasket under the motor and the gasket located where the dirt receptacle attaches to the upper cylinder Total Loss of Suction with motor running Check t...

Page 11: ...N The instructions in this booklet serve as a guide to routine maintenance For further information contact your nearest authorized BEAM dealer distributor Service Warranty Warranty is managed by our local dealer distributor ...

Page 12: ...SOLD AND SERVICED BY WWW BEAM COM 2009 Electrolux Home Care Products Ltd 460393 ...

Reviews: