background image

Operation Manual

SOTO-Y6

AIR PURIFIER

 

Before operating the system, 

please read this manual 

thoroughly, and retain it for 

future reference.

Top-Grade Air Purifier

Summary of Contents for SOTO-Y6

Page 1: ...Operation Manual SOTO Y6 AIR PURIFIER Before operating the system please read this manual thoroughly and retain it for future reference Top Grade Air Purifier ...

Page 2: ...This is Soto If you have the opportunity to experience SOTO air purifiers please remember that they are designed with our dreams to meet your expectations ...

Page 3: ...04 05 06 07 08 09 10 11 12 13 14 15 Contents Consumer Limited Warranty Safety Precautions How it Works Features and Specifications Part Name Installation Operation Care and Maintenance Troubleshooting ...

Page 4: ...ubject to normal wear unless they are defective in material or workmanship 1 Any defects caused or repairs required because of abusive operation negligence accident improper installation or inappropriate use as outlined in the operation manual 2 Any product tampered with modified adjusted or repaired by any party other than SOTO 3 Damaged caused or repairs because of the use with items not specifi...

Page 5: ... When removing the power plug always hold the plug and never pull by the cord Do not handle plug or appliance with wet hands Electrical shock or fire from short circuit may occur To avoid causing fire do not attempt to disassemble the unit only certified technicians should do this Stop the unit and unplug the power when maintenance Do not insert fingers or foreign objects into the intake or air ou...

Page 6: ... HEPA filter removes microscopic particles in the air 3 The activated carbon filter will absorb odors and gases 4 The UV lamp kill bacteria and viral microorganisms such as influenza TB and Legionnaire s Disease as well as other harmful contaminants 5 When UV light hits the photo catalytic filter it creates e and h which have an excellent effect in the decomposition of odors 6 The unit also genera...

Page 7: ...ppropriate fan speed depending on the air quality detected 2 The unit can be operated completely with the wave of your hand making it suitable in medical settings to avoid cross contamination 3 The unit is also equipped with a safety interlock switch that will turn the power off if the bottom plate is opened 4 The indicator lights tell you when to replace the HEPA filter Activated carbon filter or...

Page 8: ...sor 10 HEPA filter 11 Activated carbon filter 12 UV lamp 13 Photo catalytic filter 14 Unit lock 15 UV lamp set 16 Bottom plate 01 Unit body 02 Unit housing 03 Air outlet 04 Fan motor 05 Fan blade 06 Ion generator 07 LED display circuit board 08 Display panel 08 Part Name ...

Page 9: ...f more than 90 for indoor air Applicable places and Operation Prior to using unit for the first time you must remove the plastic bag from the HEPA filter inside the unit 1 Turn unit upside down put towel or any soft pad on the ground to avoid damage to the unit when you turn it upside down 2 Open unit from the bottom turn counterclockwise to open bottom as pictured below Pic 1 3 After the plastic ...

Page 10: ...and anything that may block the airflow nearby Installation2 C L O S E C L O S E O P E N O P E N B E S U R E T O U N P LU G THE POWER C O R D B E S U R E T O U N P L U G T H E P O W E R C O R D CLOSE OP EN OP EN B E S U R E T O U N P LU G THE POWER C O R D B E S U R E T O U N P L U G T H E P O W E R C O R D CLOSE OP EN OP EN ...

Page 11: ...ight up medium speed Wave 3 Wave a 3rd time the third circle will light up high speed Wave 4 Wave a 4th time all the circles light up white turbo speed Wave 5 Wave a 5th time the AUTO indicator will light up This is Auto Mode the unit will operate on low speed and will adjust speeds accordingly based on what pollution the sensors pick un in the air Wave 6 Wave 6th time the unit goes back to standb...

Page 12: ...hen the button is pressed it will turn off the UV lamps pressing again will turn on the UV light 4 NEG ION Button Turns Negative Ions on and off 5 NIGHT Button When pressed all the indicator lights on the display panel will go out 12 TVOC PM2 5 C 1 2 3 4 5 When the unit is not operated for one minute the PM2 5 display panel will automatically enter the screensaver state At this time the power indi...

Page 13: ...isconnect the power cord from Germicidal UV lamp take off the unit lock 3 Take out the used HEPA filter and replace with a new one 4 After replacing the HEPA filter hold the POWER button for 3 seconds to reset the time for the HEPA filter Warning To maintain optimum performance of this air purifier the HEPA filter the Activated carbon filter and the UV C bulb need to be replaced when the indicator...

Page 14: ...ist to open the UV lamp set to take out the used l UV lamp 3 Replace with a new one and put new UV lamp back in the unit close the UV lamp set re connect the power cord and put the bottom plate back on 4 Press the POWER button for 3 seconds to reset the indicator light Replacing the Activated carbon filter Replacing the UV Lamp Warning DO NOT reuse or clean the HEPA filter and the Activated carbon...

Page 15: ... sure plug is fully inserted The unit does not operate when the bottom plate is detached Install properly Check interlock switch What to check Measure The unit does not operate When functions do not work properly Case 15 Troubleshooting Service problems that appear to be major can often be solved easily You can be your own troubleshooter by reviewing the following guide All other servicing should ...

Page 16: ...Technology Langfang Co Ltd Add Certification Industrial Park Dachang High and New Technology Development Zone Langfang City Hebei Province China Tel 400 626 8883 Email customerservice soto com cn Web www sotoairpurifier com ...

Reviews: