11
5
-
MIN
MAX
FACTORY VALUES
SAFETY FIELD CONFIGURATION
3 s
max. 30 s
Launch a teach-in after changing the sensor position or when new objects are added to or changed in
the detection zone. The sensor will learn its surroundings and adapt the detection field shape to these.
Objects in the detection field will be cut out.
During teach-in, the detection field should be free of snow buildups, heavy rain, snowfall, fog or other
moving objects.
0.5 m
5.0 m
no field
Ex:
for a field width of 4.2 m
5.2 FIELD WIDTH
5.1 SAFETY FIELD TEACH-IN
After teach-in, the field width should be reduced by remote control.
During this operation there is no safety on the door!
Wait for the teach-in process to finish or lock the sensor by
remote control after min. 3 seconds:
LZR-P110 ON SWINGING DOORS