background image

Page 2 of 16 

 

75.5753.15 LZR-MICROSCAN T 20180720

CLASS 1

LASER PRODUCT

Page 2 of 16 

 

75.5753.15 LZR-MICROSCAN T 20180720

The door control unit and 
the door header must be 
correctly grounded.

Only trained and 
qualified personnel are 
recommended to install 
and set up the sensor.

Always test the proper 
operation of the 
installation before leaving 
the premises.

The warranty is void if 
unauthorized repairs are 
made or attempted by 
unauthorized personnel. 

SAFETY

It is recommended to clean the 
optical parts at least once per 
year or more if required due to 
environmental conditions.

Do not use abrasive 
cleaning components.

MAINTENANCE

Avoid extreme vibrations.

Do not cover the sensor.

Avoid moving objects and 
light sources in detection 
zone.

Avoid highly reflective objects 
in the detection zone.

INSTALLATION

IR laser (Class 1)

wavelength 905 nm
max. output pulse power 35 W

LASER

CAUTION

:  Use of controls or adjustments 

or performance of procedures other than 
those specified herein may result in hazardous 
radiation exposure.

PRECAUTIONS

READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP

 

‰

Shut off all power going to header before attempting any wiring procedures.

 

‰

Maintain a clean and safe environment when working in public areas.

 

‰

Constantly be aware of pedestrian traffic around the door area. 

 

‰

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected 
reactions by the door.

 

‰

ESD (electrostatic discharge)

:  Circuit boards are vulnerable to damage by electrostatic discharge. Before 

handling any board, ensure you dissipate your body’s ESD charge.

 

‰

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any 
wires and cause damage to equipment.

 

‰

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

 

‰

DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be 
performed by BEA, Inc. Unauthorized disassembly or repair:

1.  May jeopardize personal safety and may expose one to the risk of electrical shock.
2.  May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

Summary of Contents for LZR-MICROSCAN T

Page 1: ...50 0078 1 2 On Off Hold Open Switch Jumper 20 5310 1 1 Left Pass Through Sensor Endcap 41 7922 1 2 Right Pass Through Sensor Endcap 41 7923 1 2 Sensor Spacer 70 5554 1 2 Spacer Mount Screws Metal 50 0048 2 4 Spacer Mount Screws Wood 50 5319 2 4 Sensor Mount Screws Metal 50 1818 4 8 Sensor Mount Scews Wood 50 5282 4 8 Endcap Screws 41 8632 4 4 Velcro Tabs 50 0046 2 2 LZR microscan T Mounting Templa...

Page 2: ...n hazardous radiation exposure PRECAUTIONS READ BEFORE BEGINNING INSTALLATION PROGRAMMING SET UP Shut off all power going to header before attempting any wiring procedures Maintain a clean and safe environment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when performing tests that may result in unexpe...

Page 3: ...s closed SENSOR LED COLOR SIGNAL DESCRIPTION Green Operational Sensor operational Red Detection Sensor in detection Sensor monitoring Orange Error Sensor in error reference hub LCD CHANGING A VALUE SCROLL MENU UP DOWN PUSH TO SELECT PARAMETER SCROLL VALUES UP DOWN PUSH TO SAVE NEW VALUE current value is displayed more values are displayed new value is displayed NAVIGATING IN MENUS Push to enter th...

Page 4: ...mine on which side of door Door Loop will be installed Cut to shortest length to avoid loop in detection zone Sensors are handed Determine if the sensor you are installing is right handed or left handed The image here shows a left handed sensor On the sensor to be mounted on loop side remove the Blank Endcap closest to door hinge 1 Route Master Sensor Harness through Door Loop and plug into sensor...

Page 5: ...er most port on sensor Using instructions on Mounting Template mount SLAVE sensors with appropriate screws Plug in Slave Sensor Harness at the upper most port on sensor Install Door Loop Drill 1 2 passage hole in header and jamb then route Master Sensor Harness and install the cap Plug Master Sensor Harness into hub port labeled Door A Sensors If necessary repeat steps 1 7 for second door leaf usi...

Page 6: ...UNCTION JUMPER WIRES on red jumped to black hold open black jumped to white off none IMPORTANT All activation devices must be wired directly to hub Logic modules must be activated by hub via Door Control Harness activation wires Peripherals Install Home Switch at desired location For single doors wire nut white Home Switch wires to orange wires of System Harness plugged into hub Home Switch1 For p...

Page 7: ...ate s For complete installation instructions refer to the appropriate BEA User s Guide Wire nut push plate wires or wireless receiver COM and NO to gray wires of System Harness plugged into hub Push Plates optional INSTALLATION cont Multiple push plates can be paralleled to gray wires of System Harness If door system utilizes independent door controls repeat steps 1 2 for the second control For du...

Page 8: ... monitoring wires must be properly connected to the door control WIRING DOOR TYPE HUB PORT single always use DOOR CONTROL A hub port simultaneous pair1 from header cover side left door uses DOOR CONTROL A hub port and right door uses DOOR CONTROL B hub port dual egress1 from header cover side whichever door is pushed right door during Teach In process uses DOOR CONTROL B hub port IMPORTANT All wir...

Page 9: ...h sides For dual egress doors Push Door icon will display Push right door Door B open at least 10 degrees Once Teach In is complete LCD displays home screen Blue LED is off and orange LED is on 1 Be sure to walk test door after set up is complete and perform new Learn anytime door operator control sensor or hub is adjusted NOTES 1 Verify Home Switch is making breaking by observing orange LED on hu...

Page 10: ...en or Manual before switching to NotClosed in seconds AdvanceSafe Off On Type of safety provided while door s is are currently open due to manual operation or stack pressure Off Allows door s to activate via motion sensor or push plate On Prevents door s from activating via motion sensor or push plate Act Dist 3 12 24 48 Door closed detection distance of Approach Sensor s in inches MonitorLogic 2 ...

Page 11: ...tClosed Manual HoldOpen Off AdvanceSafe Displays current position state of door DispSens 5 A1 A2 PP MO S1 S2 HM Displays active devices A1 Approach microscan T 1 MO Motion Sensor S2 Safety microscan T 2 A2 Approach microscan T 2 S1 Safety microscan T 1 HM Home Switch Closed PP Push Plate DispPos 6 Displays opening position 0 full closed 100 full open relative to learn cycle ID Config Software Erro...

Page 12: ...ust Home Switch and verify proper wiring Cap LCD screen Learn required Perform re Learn Orange flashing LED on Sensor reference Hub for error height angle Sensor mounted too high or adjusted too close to door Verify handedness right or left handed for correct orientation EDPS Door did not open or reach full open during Learn BUS config Number of doors configured incorrectly boundary Sensor masked ...

Page 13: ...eck and adjust door for proper operation and perform a new learn Increase door speed to 9 seconds or less of opening time Home switch is not breaking soon enough Adjust the home switch to break with very little door movement Possible bad sensor gyro Replace sensor Trouble with lost pulses during learn process while door is in motion Door must move thru a full open close cycle with home switch maki...

Page 14: ...ian or cart causing sensor to shut down Set switch to OFF and allow door to see home Set switch to ON for Auto Recovery Fork Processor unable to move to next process Automatic Recovery PWR LSR Sensor power is out of tolerance Install BEA power supply PN 30 5558 PWR APD Laser Photo Diode voltage is out of tolerance Replace the sensor Motor Sensor motor RPM too low Replace the sensor Door slammed by...

Page 15: ...h lost pulses during the teach in process while door is in motion SET UP Door must move through a full open and close cycle with the home switch making and without losing pulses Verify home switch closes at door closed position 6 EDPS teach in error 2nd most common 1 Door s did not open move 2 Door s did not open at least 80 3 Door s not moving fast enough 4 Home switch s not breaking soon enough ...

Page 16: ...place BEA INSTALLATION SERVICE COMPLIANCE EXPECTATIONS Technology laser time of flight measurement Detection mode presence Detection width 20 48 measured from leading edge to sensor LED Mounting Height 75 98 measured from finished floor to sensor LED Remission factor 2 Angular resolution 2 56 Testbody 28 H x 12 W x 8 D Emission characteristics IR laser wavelength 905 nm max output pulse power 35 W...