Page 10 of 16
75.5753.15 LZR-MICROSCAN T 20180720
Page 10 of 16
75.5753.15 LZR-MICROSCAN T 20180720
OVER
VIEW OF SETTINGS
MENU
ConfiLCD DISPLA
Y
PARAMETERS
DESCRIPTION
Menu 1 (BASIC)
DoorT
ype
Undefined
Single
Pair
DualEgr
InDualEgr
Type of door system on which sensors ar
e installed:
Single
: Single Door
Pair
: Pair of Doors
DualEgr
: Dual-egr
ess Doors
InDualEgr
: Independent Dual-egr
ess Doors
DetectZoneA
1
20 –
48
Distance (in inches) fr
om sensor LED to leading edge of Door A [r
ound down]
DetectZoneB
1
20 –
48
Distance (in inches) fr
om sensor LED to leading edge of Door B [r
ound down]
Guiderail
0
– 60
Guiderail height fr
om floor (in inches)
Menu 2 (ADVANCED)
Monitoring
2
O
ff
Safe
Stall
Safe&Stall
Act
Act&Stall
Type of monitoring:
O
ff
: No Monitoring
Safe
: Monitoring of Safety Signal
Stall
: Monitoring of Stall Signal
Safe&Stall
: Monitoring of Safety & Stall Signals
Act
: Monitoring of Activation Signal
Act&Stall
: Monitoring of Activation & Stall Signals
KnowingAct
O
ff
On
Tur
ns Knowing Act
O
ff
or
On
Act:HoldT
ime
1 -
5
- 30
Time activation r
elay will be held after loss of detection (in seconds)
PushNGo
O
ff
On
Tur
ns Push-And-Go
O
ff
or
On
NotCloseT
ime
5 -
10
- 30
Time r
equir
ed for door to r
each “Closed” fr
om “Open” or “Manual” befor
e switching to “NotClosed” (in seconds)
AdvanceSafe
O
ff
On
Type of safety pr
ovided while door(s) is/ar
e curr
ently open due to manual operation (or stack pr
essur
e):
O
ff
: Allows door(s) to activate, via motion sensor or push plate
On
: Pr
events door(s) fr
om activating, via motion sensor or push plate
Act:Dist
3
12 -
24
- 48
Door closed detection distance of Appr
oach Sensor(s) (in inches)
MonitorLogic
2
ActiveLow
ActiveHigh
ActiveLow
: 0V r
equests monitoring
ActiveHigh
: > 0V r
equests monitoring
Safe:Dist
3
Deep
Medium
Limited
Door closed detection distance of Safety Sensor(s):
Deep
: 4 curtains
Medium
: 3 curtains
Limited
: 2 curtains
Traf
fic
Normal
High
Extr
eme
When doors do not come closed for a certain period of time due to traf
fic flow
Normal
: ≤ 5 min
High
: ≤ 30 min
Extr
eme
: > 30 min
Default parameters are in BOLD. Menu 1 (Basic) items MUST be programmed.
NOTES
:
1.
Detection zone “A” and “B” ar
e the sensor patter
n width and ar
e determined by measuring the distance fr
om the sensor LED to the leading edge of the door
.
2.
The sensor LED will briefly flash RED during monitoring communication with door contr
ol. This indicates that exter
nal monitoring is functional. Monitoring functionality must be active on the sensor
and monitoring wir
es must be pr
operly connected to the door contr
ol.
3.
The Appr
oach Side Detection Zone (Act:Dist) and Swing Side Safety Zone (Safe:Dist) ar
e independently adjustable.