Page 3 of 3
75.0062 V2 Mar 2002 [Rev. 3/06/2002]
DIP SWITCH
SETTINGS
SET-UP
INSTRUCTIONS
COMPANY
CONTACT
Once all components are properly wired together, power can be applied and the set-up can begin. Only one
adjustment is necessary on the LE-21 and that is the hold open time delay for the door when the door is operated
automatically. This adjustment is in the form of five dip switches located on the right side of the unit, which can be set
to achieve a 0 to 31 second hold open time delay. The hold open time delay should be set for the length of time the
door should remain open once the push plate has been released. Since the LE-21 provides the hold open time delay,
the time delay on the operator must be set to minimum.
The LED’s on the LE-21 let the installer know that the LE-21 is in operation. The RED LED signifies that the push
plate has been activated and the LE-21 is activating and holding the door open. The RED LED will light as soon as
the push plate is activated and remain lit for the hold time preset by the installer (once the push button is released).
The GREEN LED signifies that the SuperScan’s input to the door control will be accepted. When the GREEN LED is
on, the SuperScan is capable of reactivating the door if something is in the swing path of the door. The GREEN LED
will shut off as soon as the door position switch sends a closed signal to the LE-21 to tell the LE-21 that the door is
closed. Once the door is closed and the GREEN LED is off the LE-21 will ignore the input of the SuperScan until the
push plate activates the door again.
1. Use the chart provided below to configure the time delay for the LE-21. By default, the unit is set to 7 seconds.
Only dipswitches 1 through 5 are used for this function.
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc.
for further assistance during
Eastern Standard Time at 1-800-523-2462 from 8am - 5pm
.
For after-hours, call East Coast: 1-866-836-1863 or 1-800-407-4545 / Mid-West: 1-888-308-8843 /
West Coast: 1-888-419-2564.
DO NOT leave any problem unresolved.
If you must wait for the following
workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made.
NEVER sacrifice the safe operation of the automatic door or gate for an incomplete solution.
Web: www.beasensors.com
Set the dip switches according to the chart below to
achieve the desired hold open time delay. The dip
switches are configured to send a binary coded input
to the microprocessor to establish the correct time
delay.
Dip Switch 1 = 1 second
Dip Switch 2 = 2 seconds
Dip Switch 3 = 4 seconds
Dip Switch 4 = 8 seconds
Dip Switch 5 = 16 seconds
Dip Switch 6 = not used
Dip Switch 7 = not used
Dip Switch 8 = not used
time
delay
(sec)
dip 1
1 sec
dip 2
2 sec
dip 3
4 sec
dip 4
8 sec
dip 5
16 sec
time
delay
(sec)
dip 1
1 sec
dip 2
2 sec
dip 3
4 sec
dip 4
8 sec
dip 5
16 sec
1
on off off off off
17
on off off off on
2
off on off off off
18
off on off off on
3
on on off off off
19
on on off off on
4
off off on off off
20
off off on off on
5
on off on off off
21
on off on off on
6
off on on off off
22
off on on off on
7
on
on
on
off
off
23
on on on off on
8
off off off on off
24
off off off on on
9
on off off on off
25
on off off on on
10
off on off on off
26
off on off on on
11
on on off on off
27
on on off on on
12
off off on on off
28
off off on on on
13
on off on on off
29
on off on on on
14
off on on on off
30
off on on on on
15
on on on on off
31
on on on on on
16
off off off off on