background image

 

Page 1 of 3 

 

75.0062 V2 Mar 2002 [Rev. 3/06/2002] 

PRODUCT 
DESCRIPTION

 

COMPONENT ID 

 

TECHNICAL  
SPECIFICATIONS

 

SAFETY 
PRECAUTIONS

 

 

 

  

 
 
 
 

 
The LE-21 (PN: 10LE21) is a lock out module that has been designed to inhibit the Approach SuperScan on an 
automatic door when the door is used manually.  For instance, when the SuperScan is installed on a low energy 
operator that is to be used manually as well as automatically, the LE-21 will allow the SuperScan to be active only 
when the door is triggered by activating a push plate, such as on “knowing act” doors.  The SuperScan will remain in 
the activation circuit until the door fully closes following the automatic operation of the door.  A door position switch 
must be used to indicate to the LE-21 that the door has reached its fully closed position and to ignore the input of the 
SuperScan until the push plate activates the door again.  If the door is opened manually, the LE-21 will prohibit the 
input from the SuperScan from reaching the door control.   The LE-21 provides the hold open time delay; therefore, 
the door control’s time delay should be set to minimum.

 

 

 

 
 

 

 

 
 
 
 
 
 
 
 

 

 
 
 

 

 

 

   

 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

 
 
 

 

 
 
 

 

• 

Shut off all power going to the header before attempting any wiring procedures. 

• 

Maintain a clean & safe environment when working in public areas. 

• 

Constantly be aware of pedestrian traffic around the door area. 

• 

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected 
reactions by the door. 

• 

Always check placement of all wiring before powering up to insure that moving door parts will not catch 
any wires and cause damage to equipment. 

• 

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10 or A156.19) upon 
completion of installation. 

 

 

 

  TECHNICAL SPECIFICATIONS 

 

Power Supply 

12-24 Volts AC / 15-24 Volts DC 

Operating Frequency 

4 MHz (Microprocessor) 

Power Consumption 

10 mA at rest, 50 mA Max. 

Output 

2 X SPST Relays 

Max. Voltage - Relay Contact 

60V DC, 120V AC 

Max. Current - Relay Contacts 

2A DC, 0.5A AC 

USERS GUIDE

 

LE-21 

SUPERSCAN LOCK OUT RELAY 

                 Dipswitches 
         Green LED – Activation Allowed   
                              by SuperScan 
 
Red LED – Activation is Being Sent To 
                  Door Control 

Reviews: