background image

 

Page 2 of 3 

 

75.0062 V2 Mar 2002 [Rev. 3/06/2002] 

ELECTRICAL 
INSTALLATION  

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

    

WIRE CONNECTIONS 

Orange 

Power input / 12-24 VAC or 15-24 VDC (-) 

Brown 

Power input / 12-24 VAC or 15-24 VDC (+) 

Yellow 

Control Box Active N.O. 

Green 

Control Box & SuperScan  COM 

Red SuperScan 

N.O. 

Gray 

Door Position Switch N.O. 

Gray 

Door Position Switch COM  

Blue 

Push Plate N.O. 

Blue 

Push Plate COM 

 

IMPORTANT NOTE: 

The Door Position Switch must be used for all applications, and the switch must be a normally closed circuit. That is, 
the switch must provide a closed contact when the door is fully closed. 

 

blue

blue

yellow

green

red

LE-21

brown

orange

PUSH
  TO
OPEN

PUSH
  TO
OPEN

24 V 
TRANSFORMER

115 VAC

COM

N/O

N/O

COM

DOOR CONTROL

COMMON

ACTIVATION

BLANK  1

INHIBIT GND 2

I 3

N.C. 4

N.O. 5

COM 6

POWER 7

POWER 8

BLANK  1

INHIBIT GND 2

I 3

N.C. 4

N.O. 5

COM 6

POWER 7

POWER 8

SINGLE DOOR

PAIR OF DOORS

gray

gray

COM

N/O

DOOR POSITION
SWITCH

APPROACH SIDE

APPROACH SIDE

Closed contact when
door is closed.

 
 

 

 

 

 
 

red

gray
blue

yellow

orange

brown

blue

gray

green

LE-21

SuperScan 

Lock Out Relay

Reviews: