1. INTRODUCTION 

The new 

NIVOROTA E-700/800 

rotary paddle level switches of the well-known NIVELCO design can be 

used for detecting the level of lumpy materials, powders, and granules. Mounted onto tanks, silos, and 
hoppers, they monitor and control the level, filling, and emptying of stored materials such as stones, fly ash, 
sand, coal, feed, beet slices, etc. 
A low-power electric motor drives the paddle, which rotates freely in the absence of the material. Its rotation 
in the 

EK

 / EH

 is mono-directional; in the 

EL

 / EM

, it is bidirectional. When the medium reaches the 

paddle, the output contact switches from NC state to NO state, and the motor is turned off. When the material 
level drops, the paddle runs free again, the motor is reactivated, and the switch returns to its original state 
(NC). In the case of low-level detection, the material usually covers the blade, with the output contact staying 
in NO state, and the motor stopped. When the material drops to a level where the paddle can rotate freely 
again, the motor restarts and the control switch returns to the NC position. 
The process connection can be threaded (1" or 1½" BSPT) or a mounting plate. It is recommended to use 
adapters for threaded connection points other than the standard version. The mounting plate can be attached 
to the unit with a threaded process connection. Mounting nuts are available for mounting onto a bracket, 
depending on the size of the process connection. A suitable paddle must be chosen for every particular 
medium density. The single-blade paddle is recommended for higher density materials and granular solids, 
while the 3-blade paddle is recommended for lower density materials, powders, and solids. The 1-blade 
paddle or 2-blade paddle with flexible coupling can also be used with a suitable threaded connection, while 
the 3-blade paddles can only be installed using a mounting plate. 
If the standard version's insertion length is not enough, there are rod or cable extension types available, 
depending on the application. For light materials with moderate stress, the solution is to use (Ø10) pipe 
extension. The device's shaft must be protected against being hit by falling stones or other coarse materials 
by using a flexible coupling. If the insertion length is customized for any technical reason, the rod-extended 
design with an adjusting unit is recommended. This can be ordered separately. In the case of a cable 
version, if the desired length falls between two available sizes, the desired length can be achieved by cutting 
the cable to the appropriate size. The counterweight stretches the cable to avoid the paddle climbing up onto 
the medium surface. If additional stiffening of the cable probe is required, a rigid pipe can be ordered as an 
accessory.  

Caution! If the pipe is cut to size, at least 30 mm (1.2 inches) must be left free between its top end and 
the cable rope assembly connector. 

If the medium temperature exceeds 120 °C (248 °F), a high-temperature version must be used, equipped 
with a heat sink, raised from the process connection, and only available with aluminum housing.  
Dust-Ex versions are available for use in hazardous environments. 

2. TECHNICAL DATA 
2.1

 

G

ENERAL DATA

 

 

Version 

Standard 

High-temperature 

EM

– / EH

–7



 

EL

– / EK

–7



 

EL

– / EK

–8



 

Insertion length (L) 

Standard: 200 mm (7.85 inches) – Rod extension: 0.3…3 m (1…10 ft) 

Cable extension: 1…3 m (3.3…10 ft) 

Number and material of the 
blades 

1.4571 (316Ti) / 1, 2, 3; as per order code 

Rotation speed 

~1 rpm (@50 Hz) 

Material of wetted parts 

1.4571 (316Ti) Stainless Steel, Material of the seal: NBR 

1.4571 (316Ti) Stainless Steel, Material of the seal: FPM 

Medium density (guideline value) 

min. 0.1 kg/dm

3

 

Medium temperature 

-20…+120 °C (-4…+248 °F) 

-20…+80 °C (-4…+176 °F) 

-20…+200 °C (-4…+392 °F) 

Ex variant: see 2.2 Explosion protection data 

Ambient temperature 

-30…+60 °C (-22 °F … +140 °F) 

Relative humidity 

max. 90% 

Process pressure 

max. 3 bar (0.3 MPa, 43.5 psig) 

Output 

SPDT 250 V AC, 6 A, AC1 

Paddle-rotation / shutdown 
indication 

Two-toned (green/red) LED 

Power supply 

Nominal value: 230 V AC (50/60 Hz) +10% -15%, 120 V AC (50/60 Hz) +10% -15%  

24 V AC (50/60 Hz) +10% -15%, 24 V DC (18…28 V DC) 

(1)

 

Process connection 

1" BSPT; 1½" BSPT; mounting plate  

(BSPT thread can also be screwed into BSP or NPT thread) 

Power consumption 

max. 4 VA (4 W) 

Electrical connection 

2x M20x1.5 plastic cable glands, for Ø6…Ø12 mm (Ø0.25…Ø0.5 inches) cable  

2x internally threaded ½" NPT connection for protective pipes  

2x terminal blocks for 0.5…1.5 mm

2

 (AWG20…AWG15) wire cross section  

Electrical protection 

Class I. 

Ingress protection 

IP67 

Housing material 

Powder-coated aluminum 

Plastic (PBT) 

Powder-coated aluminum 

Weight 

Standard: 1.6 kg (3.52 lb), Rod-extended: 1.6 kg (3.52 lb) + extension 1.6 kg/m (1 lb/ft), 

Cable-extended: 2.6 kg (5.73 lb) + extension 1.4 kg/m (0.94 lb/ft), counterweight: 1 kg (2.2 lb) 

(1)

 

A

EK

 

/

 

EH



–4M,

 

–8M

 

use 24

 

V

 

DC

 

(-15%...+10%) 

The connection between the device housing and the process connection is rigid, it cannot be turned or twisted!