IR presence sensing field: select the applicable IR lens – narrow or wide (default)

 

 

 

 

 

 

 

Install the applicable lens into the slots  

at bottom side of sensor.  

The default lens is wide.

 

 

 

 

 

 

 Above 10’ mounting height, use the narrow prism! 

 
 

 

 

 

IR presence sensing field : Adjust the infrared curtain as shown below.  
For automatic sliding doors the curtain should reach within 3” of the face of the sliding door panel.

 

 

 

 
 
 

+4°

-4°

The pin shown 
here above 
indicates the 
angle adjusted. 

 

To approach the 
curtain to the 
door, turn the 
screw clockwise. 
To tilt the curtain 
out, turn the screw 
counterclockwise. 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 Keep 

minimum distance of 2” 

  between the door and the first 

 curtain.

 

 

 

Use the Spotfinder (accessory) 
to locate and adjust the position 
of the curtains.

 

 

 

 

 

 

 

 

When mounting one sensor on each side of the door above a highly reflective threshold, select different frequencies 
to avoid crosstalk between the sensors.

 

 

 
 

 
 
 

 
 
 
 
 

 

 

Important User Guide Symbols

 

 

 

 

 

 

 

 

 

LED turns on 

  LED flashing slowly    LED flashing quickly    Presence detection 

 

LED display during normal function 

 

 

 

 

RED LED  

Presence detection  

 

 

 

 

ORANGE LED 

See chapter 7: Troubleshooting 

 
 

2 curtains of 24 overlapping spots

(no holes between spots)

2 curtains of 12 overlapping spots 

(no holes between spots)

4  Remote Control Set-up 

Summary of Contents for IRIS

Page 1: ...elay Configuration By default it is set to Active value 4 the IRIS relay contact closes upon detection If passive is required change the output configuration value to 1 The most obvious indication to this condition is that the door works in reverse order no detection results in hold open Pulse Frequency If an interference is suspected from other nearby sensors or IR equipment change the frequency ...

Page 2: ... 8 oz Housing material ABS LURAN S Minimum length of cable 10 3 m 9 conductor 10IRIS 30 9 m 9 conductor 10IRIS I Range of Remote Control 16 PRESENCE SENSOR Detection mode Presence Response time 128ms Technology Focused active infrared and self monitored microprocessor Spot diameter standard 4 max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field 7 Ht Width Depth Wide 6...

Page 3: ...ir may jeopardize personal safety and may expose one to the risk of electrical shock may adversely affect the safe and reliable performance of the product will result in a voided product warranty 2 Mounting the sensor follow the instructions on the enclosed template Mount the sensor at a maximum height of 2 from the bottom line of the door operator Use the mounting template to drill holes and posi...

Page 4: ...e screw clockwise To tilt the curtain out turn the screw counterclockwise Keep a minimum distance of 2 between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors 1 Important User Guide Sy...

Page 5: ... will once again be required unless it is deleted as described below To re lock the sensor without a lock code or with a new lock code perform the following To return to no lock code simply press lock once followed by 0000 3 Remote Control Programming Launch a setup by performing the following Unlock the sensor to enter into adjustment session RED LED Press Unlock key flashes slowly To launch an a...

Page 6: ...door permanently open red LED ON 3 door permanently closed red LED OFF No monitoring reply Installation Configuration Mounting Height Pulse Frequency SINGLE UNIT 1 Low Low 2 High Low 3 Low High 4 High High OVERLAPPING UNITS 5 Low Low 6 High Low 7 Low High 8 High High Important Note Upon detection at the sensor both relays will be simultaneous triggered Relay 1 is assigned to the white and green ou...

Page 7: ...ty level is set to Snow Mode a specific trigger is required to enter into the mode If the sensor completes 2 learn cycles within 6 detections it will enter into Snow Mode During this mode the sensor will change the 2 nd infrared curtain the one farthest from the door to IR motion as opposed to IR presence Additionally the automatic learn time will change from whatever it was set to to 10 seconds T...

Page 8: ...mended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering To enter a lock code simply press the Lock key followed by a lock code If lock code is less than 4 digits the lock key must be pressed a second time following the last digit of ...

Page 9: ...f the infrared curtains emitted by the IRIS PN 10WCA WCA This is a ceiling adaptor for use on drop ceilings or otherwise Maximum ceiling thickness allowed is about PN 10WMB WMB This is a 90 degree mounting bracket to allow installation on a flat horizontal surface PN 10URC URC This is a universal rain cover to shield the sensor from direct rain contact 6 Accessories sold individually ...

Page 10: ...counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Improper door control configuration Verify that Door Control F2 is set to Normal The presence detection is dis...