SYMPTOMS 

POSSIBLE CAUSES 

CORRECTIVE ACTION 

Red LED flashing quickly after an assisted 
setup. 

The sensor ‘sees’ the door movement and 
can not finish its setup. 

Adjust the position of the IR curtains. 

Orange LED permanently ON after an 
assisted setup. 

The sensor encounters a signal saturation. 

Use the wide-field prism and/or slightly increase the IR curtains angle 
(turning the screw counterclockwise). 

Red LED permanently ON after an assisted 
setup. 

The sensor fails the IR test. 

Cut and restore the power supply. 
Launch a new assisted setup. 
If the LED still stays ON, replace the sensor. 

Orange LED ON  

The sensor encounters a signal saturation. 

Use the wide-field prism and/or slightly increase the IR curtains angle 
(turning the screw counterclockwise). 
Launch an assisted setup. 

Orange LED flashes 

The sensor signals an internal fault. 

Cut and restore the power supply. 
If the orange LED lights up again, replace faulty sensor. 

Red LED ON 

The sensor detects a presence. 

Wait the time set in ‘maximum duration of presence detection’ setting or 
launch an assisted setup (with the remote control or right push button). 

Unwanted presence detection 

The sensor is not placed properly  
and/or the front face is not properly fixed. 

Fasten the sensor firmly and/or  
check whether the front face prism is placed into the foreseen slides  
and not in the sensor cover. 

Door keeps recycling open-closed. 

The sensor is disturbed by the door motion 
because it sees the door or because of 
vibrations. 

Increase the IR curtains angle (turning the screw counterclockwise). 

The door is not closing. 
LED OFF 

On-Off switch at door control is in wrong 
position or is faulty. 

Check to insure that On-Off switch for door is in the ON or 
AUTOMATIC position.  

 

Improper output configuration on the sensor.  Check the output configuration setting on each sensor. 

 

Improper door control configuration 

Verify that ‘Door Control’ (F2) is set to ‘Normal’ 

The presence detection is disturbed by the 
rain (red LED) 

Heavy Rain 

Increase the immunity of the curtains (immunity 2 or 3) 
Install a universal rain cover (PN: 10URC) 

The sensor does not respond to the remote 
control. 

1. Batteries in the remote control are dead or 
not installed properly. 
2. Remote control badly pointed. 

1. Check to insure that the batteries are installed correctly or replace 
batteries. 
2. Point the remote control directly towards the sensor and move closer 
if necessary. 

The sensor does not unlock when access 
code is entered. 
 

Improper code being entered. 

Cut and restore power supply. No code is required to unlock during the 
first minute after powering. Press UNLOCK, then LOCK and introduce 
a new access code (See Page 5). 

 

 
 

 

7 Troubleshooting 

10 Company Contact 

 

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a 
problem, please call BEA, Inc.  If you must wait for the following workday to call BEA, leave the door 
inoperable until satisfactory repairs can be made.   Never sacrifice the safe operation of the automatic door 
or gate for an incomplete solution. 

 

 

 

The following numbers can be called 24 hours a day, 7 days a week.  For more information, visit 

www.beasensors.com

.   

 

 
 
 

US and Canada: 1 866.249.7937 

Southeast: 1 800.407.4545 

Canada: 1 866.836.1863

 

Midwest: 1 888.308.8843 

Northeast: 1 866.836.1863 

West: 1 888.419.2564 

 

 

 

Summary of Contents for IRIS

Page 1: ...elay Configuration By default it is set to Active value 4 the IRIS relay contact closes upon detection If passive is required change the output configuration value to 1 The most obvious indication to this condition is that the door works in reverse order no detection results in hold open Pulse Frequency If an interference is suspected from other nearby sensors or IR equipment change the frequency ...

Page 2: ... 8 oz Housing material ABS LURAN S Minimum length of cable 10 3 m 9 conductor 10IRIS 30 9 m 9 conductor 10IRIS I Range of Remote Control 16 PRESENCE SENSOR Detection mode Presence Response time 128ms Technology Focused active infrared and self monitored microprocessor Spot diameter standard 4 max Number of spots 24 or 12 spots by curtain Number of curtains 2 Detection field 7 Ht Width Depth Wide 6...

Page 3: ...ir may jeopardize personal safety and may expose one to the risk of electrical shock may adversely affect the safe and reliable performance of the product will result in a voided product warranty 2 Mounting the sensor follow the instructions on the enclosed template Mount the sensor at a maximum height of 2 from the bottom line of the door operator Use the mounting template to drill holes and posi...

Page 4: ...e screw clockwise To tilt the curtain out turn the screw counterclockwise Keep a minimum distance of 2 between the door and the first curtain Use the Spotfinder accessory to locate and adjust the position of the curtains When mounting one sensor on each side of the door above a highly reflective threshold select different frequencies to avoid crosstalk between the sensors 1 Important User Guide Sy...

Page 5: ... will once again be required unless it is deleted as described below To re lock the sensor without a lock code or with a new lock code perform the following To return to no lock code simply press lock once followed by 0000 3 Remote Control Programming Launch a setup by performing the following Unlock the sensor to enter into adjustment session RED LED Press Unlock key flashes slowly To launch an a...

Page 6: ...door permanently open red LED ON 3 door permanently closed red LED OFF No monitoring reply Installation Configuration Mounting Height Pulse Frequency SINGLE UNIT 1 Low Low 2 High Low 3 Low High 4 High High OVERLAPPING UNITS 5 Low Low 6 High Low 7 Low High 8 High High Important Note Upon detection at the sensor both relays will be simultaneous triggered Relay 1 is assigned to the white and green ou...

Page 7: ...ty level is set to Snow Mode a specific trigger is required to enter into the mode If the sensor completes 2 learn cycles within 6 detections it will enter into Snow Mode During this mode the sensor will change the 2 nd infrared curtain the one farthest from the door to IR motion as opposed to IR presence Additionally the automatic learn time will change from whatever it was set to to 10 seconds T...

Page 8: ...mended to set sensors close to each other with remote control The access code can be composed of 1 to 4 digits factory values or no access code 0 or 0000 No code is required to unlock during the first minute after powering To enter a lock code simply press the Lock key followed by a lock code If lock code is less than 4 digits the lock key must be pressed a second time following the last digit of ...

Page 9: ...f the infrared curtains emitted by the IRIS PN 10WCA WCA This is a ceiling adaptor for use on drop ceilings or otherwise Maximum ceiling thickness allowed is about PN 10WMB WMB This is a 90 degree mounting bracket to allow installation on a flat horizontal surface PN 10URC URC This is a universal rain cover to shield the sensor from direct rain contact 6 Accessories sold individually ...

Page 10: ...counterclockwise The door is not closing LED OFF On Off switch at door control is in wrong position or is faulty Check to insure that On Off switch for door is in the ON or AUTOMATIC position Improper output configuration on the sensor Check the output configuration setting on each sensor Improper door control configuration Verify that Door Control F2 is set to Normal The presence detection is dis...

Reviews: