75.5367.08 UL MAGLOCKS 1200lb 20210806
Page 4 of 5
The product must be powered from a UL-listed, regulated, power-limited, power supply.
12 VDC INPUT
- Required power: 0.5 AMP / 12 VDC
- Connect positive (+) lead from a 12 VDC power source to Terminal 1.
- Connect negative (-) lead from a 12 VDC power source to Terminal 2.
- Check jumper for 12 VDC operation.
24 VDC INPUT
- Required power: 0.25 AMP / 24 VDC
- Connect positive (+) lead from a 24 VDC power source to Terminal 1.
- Connect negative (-) lead from a 24 VDC power source to Terminal 2.
- Check jumper for 24 VDC operation.
POWER
If power switch is not wired between DC source v) and magnet, it will take a longer time to de-energize the magnet simulating
residual magnetism.
Page 2 of 2
75.5366.02 20140401
5 Installation - Mechanical & Electrical
LOCK ST
ATUS SWITCH (SPDT)
POWER
SUPPL
Y
+ -
POWER
SELECT
OR
JUMPER
LED
MAG BOND SENSOR
MAGNET
TIMER (0-90 SEC)
TYPICAL INSTALLATION
NOTE: DO NOT over-tighten the armature plate. The rubber washer is designed to allow the armature
plate to automatically adjust position for best mating position between the lock and armature plate.
DOOR FRAME
ARMATURE PLATE
MAGNET
ANGLE
BRACKET
MOUNTING
PLATE
MOUNTING
PLATE
STRINGER
HOLE FOR
GUIDE PIN
HOLE FOR NUT
RUBBER WASHER
STEEL WASHER
ARMATURE PLATE
SCREW M8 (35MM)
GUIDE PIN
DOOR
NUT
SPACER
WASHER
ARMATURE
PLATE
DOOR
NUT
DOOR FRAME
DOOR FRAME
DOOR
ARMATURE PLATE
ARMATURE PLATE
MAGNET
MAGNET
DOOR
DOOR
MOUNTING
PLATE
CAUTION: Observe proper
circuit board orientation!
NOTE: The product must be powered from a UL listed, regulated, power limited, power supply.
NOTE: If power switch is not wired between DC source voltage and magnet,
it will take a longer time to de-energize the magnet simulating residual magnetism.
1. 12 VDC INPUT
A. Required power 0.5A (Max).
B. Connect ground (-) lead from a 12 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 12 VDC power source to Terminal 1.
D. Check jumper for 12 VDC operation.
2. 24 VDC INPUT
A. Required power 0.25A (Max).
B. Connect ground (-) lead from a 24 VDC power source to Terminal 2.
C. Connect positive (+) lead from a 24 VDC power source to Terminal 1.
D. Check jumper for 24 VDC operation.
3. CONTACTS
1. Relay dry contacts are rated 1A at 24 VDC for safe operation, DO NOT exceed this
rating.
2. If a NO switch is required, connect the wires from the system to Terminal 4 & Terminal 3.
3. If a NC switch is required, connect the wires from the system to Terminal 4 & Terminal 5.
DS VERSION