FOLD ON DOTTED LINE

(1/8")

DRILL 3.2mm HOLE

(2 PLACES)

PLACE AGAINST DOOR

(11/16")

DRILL 16mm HOLE

TEMPLATE

PLACE AGAINST JAMB

OPPOSITE HINGES FOR

L.H.R. DOOR INSTALLATION

PLACE AGAINST HEADER

185mm ARMATURE PLATE GUIDE PIN HOLE

[6mm(1/4") DIA, 12.5mm(1/2") DEEP]

185mm ARMATURE PLATE

[6mm(1/4") DIA, 12.5mm(1/2") DEEP]

PLACE AGAINST JAMB

OPPOSITE HINGES FOR

R.H.R. DOOR INSTALLATION

STEP 1

FOLD TEMPLATE ALONG DOTTED LINE.
PLACE TEMPLATE AGAINST DOOR AND HEAD FRAME.
DRILL HOLES AS INDICATED ON TEMPLATE.

STEP 2

MOUNT THE ARMATURE PLATE TO DOOR USING

1 RUBBER WASHER SANDWICHED BETWEEN 2 STEEL

WASHER (THE RUBBER WASHER AND 2 STEEL

WASHER ARE INSTALLED ON THE THROUGH SEXNUT

BETWEEN THE ARMATURE PLATE AND DOOR).

STEP 3

DETACH MOUNTING PLATE FROM MAGNET BY REMOVING

2 SOCKET CAP SCREWS. SCREWS COULD BE ACCESSED

THROUGH BOTTOM OF MAGNET.

INSTALL THE MOUNTING PLATE WITH 2 FLAT HEAD

SCREWS (THE 2 M5x15 FLAT HEAD SCREWS ARE

INSTALLED IN THE SLOTTED HOLES FOR ADJUSTMENT).
ADJUST MOUNTING PLATE SO THAT IT FORMS A RIGHT

ANGLE WITH THE ARMATURE PLATE.


USING THE MOUNTING PLATE AS A TEMPLATE,DRILL

THE WIRE HOLE.

DRILL AND INSTALL THE REMAINING MOUNTING SCREWS.

STEP 4

INSTALL MAGNET TO MOUNTING PLATE WITH

2 M6 SCREWS SUPPLIED.

INSTALL ELECTRICAL WIRING PER

INSTRUCTION SHEET.

STEP 5

TEST ALL FUNCTIONS OF THIS MODEL (SEE

WIRING INSTRUCTION).

STEP 6

INSERT 2 LOCKING STOPPERS IN TWO END

PLATES,AND COVER WITH 4 mm SCREWS.

STEP 7

INSERT 2 ALUMINUM CAPS TO COVER THE

TWO M6 SCREW HOLES.

STEP 8

NOTE: IF NEEDED, USE SMALL MAGNET TO

REMOVE LOCKING STOPPERS FROM HOLES.

DWG. NO. 820001

75.5367.08 UL MAGLOCKS 1200lb 20210806  

Page 2 of 5

 

5

Handle the equipment with care.  Damaging the mating surfaces of the magnet and armature plate may reduce locking efficiency.

 

5

The MAGLCOK mounts rigidly to the door frame.  The armature plate mounts to the door with the hardware provided.  This allows the armature plate to pivot about its 

center to compensate for door wear and misalignment.

 

5

You must only use the template with the door in its normally closed position.

 

5

Add threadlocker to all screws before installing, and firmly tighten screws.

 

5

Install only for indoor, dry applications.

 

5

Installation and wiring must be performed in compliance with ANSI / NFPA 70 / NFPA 101 / CSA C22.1, Canadian Electrical Code, Part I, safety standard for electrical 

installations, section 32; and CAN/ULC-S524 installation of fire alarm system requirements.

 

5

The MAGLOCK shall be installed within the same room as other equipment and circuitry connecting to the MAGLOCK.

 

5

Wiring must be cased to avoid outer cable damage, affect the insulation distance.

 

5

An electric locking mechanism shall not impair the operation of panic hardware mounted on the door.

 

5

An electric locking mechanism shall not impair the intended operation of an emergency exit.

 

5

Shut off all power going to header before attempting any wiring procedures.

 

5

Maintain a clean and safe environment when working in public areas.

 

5

Constantly be aware of pedestrian traffic around the door area.

 

5

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

 

5

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment 

or cable insulation.

 

5

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

DO NOT over-tighten the armature plate.  

The rubber washer is designed to allow the armature plate to automatically adjust position for best mating position between the magnet and armature plate.

DOOR FRAME

DOOR FRAME

DOOR FRAME

MAGNET

MAGNET

MAGNET

DOOR

DOOR

DOOR

MOUNTING PLATE

Use the applicable mounting template.  

See image of template below.

See User’s Guide 75.5643 for U-bracket 

installation (to be used with glass doors).

MOUNTING PLATE

L&Z BRACKET

FILLER

ARMATURE PLATE

ARMATURE PLATE

ARMATURE PLATE

Filler

L&Z bracket

3   Precautions

4   Installation Notes

5   Installation 

 Mechanical

Mounting Options

TYPICAL INSTALLATION

!

CAUTION

Summary of Contents for 10MAGLOCK1UL

Page 1: ...each Dimensions 10 47 x 2 87 x 1 58 in 266 x 73 x 40 mm 20 94 x 2 87 x 1 58 in 532 x 73 x 40 mm Certification UL1034 UL294 UL1034 UL294 Operating Temperature 32 120 F 0 49 C 32 120 F 0 49 C Operating Humidity 0 85 0 85 UL 294 Performance Ratings required per Chapter 10 of 2015 IBC Destructive Level I Line Security Level I Endurance Level IV Standby Power Level I Static Strength 1000 lb Dynamic Str...

Page 2: ... wear and misalignment 5 You must only use the template with the door in its normally closed position 5 Add threadlocker to all screws before installing and firmly tighten screws 5 Install only for indoor dry applications 5 Installation and wiring must be performed in compliance with ANSI NFPA 70 NFPA 101 CSA C22 1 Canadian Electrical Code Part I safety standard for electrical installations sectio...

Page 3: ...er 5 steel washer 6 armature plate 7 permanent magnet 8 guide pin Align the black plastic piece of the armature plate with the cover plate i e magnet must line up with the switch DOOR SIDE VIEW armature plate nut rubber washer timer LED bond sensor power selector jumper magnet 12 VDC 24 VDC power supply green N O N C COM black red dry contact lock status switch CIRCUIT BOARD NOTE Terminals ratings...

Page 4: ...NET ANGLE BRACKET MOUNTING PLATE MOUNTING PLATE STRINGER HOLE FOR GUIDE PIN HOLE FOR NUT RUBBER WASHER STEEL WASHER ARMATURE PLATE SCREW M8 35MM GUIDE PIN DOOR NUT SPACER ARMATURE PLATE DOOR NUT DOOR FRAME DOOR FRAME ARMATURE PLATE ARMATURE PLATE MAGNET MAGNET DOOR DOOR MOUNTING PLATE CAUTION Observe prop circuit board orientation The product must be powered from a UL listed regulated power limite...

Page 5: ...BLACK LIGHT COM REED SWITCH ON DOOR STATUS SENSOR SWITCH Switch changes state when door is open NO BEA Inc the sensor manufacturer cannot be held responsible for incorrect installations or incorrect adjustments of the sensor device therefore BEA Inc does not guarantee any use of the sensor device outside its intended purpose BEA Inc strongly recommends that installation and service technicians be ...

Reviews: