USEFUL TIPS & RECOMMENDATIONS 

The  installation  of  this  appliance  must  be  carried  out  by  a  competent  person,  and  in 
accordance  with  the  requirements  of  the  GAS  SAFETY  (INSTALLATION  AND  USE) 
REGULATIONS.
 

As with any fire, certain components will become hot in use e.g. the decorative front fret. 
Care  should  be  exercised  when  using  the  controls  of  the  appliance  when  it  is  hot.  We 
also  recommend  that  a  fireguard,  conforming  to  BS  6539  or  BS  6778,  be  fitted  for  the 
protection of young children, the elderly or infirm. 

When new, the ceramic coals may produce a slight odour, but this will completely vanish 
after a few hours of use. 

Handle  coals  gently.  They  are  fragile.  A  soft  brush  can  be  used  to  clean  them  of  any 
excess  soot.  UNDER  NO  CIRCUMSTANCES  should  coals,  pebbles  or  ceramics  be 
washed. 

Never throw cigarette ends or other foreign matter onto the fire. 

Never leave the house unattended, with the fire alight. 

Check periodically that any purpose made ventilation is free from obstruction. 

To  obtain  the  best  results  from  your  fire,  we  recommend  that  the  fire  be  serviced 
annually. 

These instructions are provided to assist you to operate the fire correctly and should be 
kept in a safe place. 

10 

This appliance is intended for decorative purposes. 

11 

This appliance is fitted with a flue blockage device that will shut off the appliance in the 
event of abnormal flue conditions. This device is NOT a substitute for an independently 
mounted carbon monoxide detector. 

12 

 During the summer, when the appliance is not in use, we recommend that it be turned on 
from  time  to  time  to  get  the  fan  running  and  some  air  passing  across  the  electronic 
controls.  Fires  which  have  been  left  inoperative  throughout  the  summer  months  may 
exhibit fault conditions but these are often caused by a lack of use.  

 

 

25    OPERATION OF YOUR APPLIANCE 

 

It should be noted that your fire is fitted with a Flame Supervision Device which cuts off 
the gas supply to your fire if for any reason the pilot light is extinguished.  It also monitors 
constantly  the  oxygen  in  the  room.    The  pilot  flame  heats  the  thermocouple  probe  and 
allows gas to flow to the burners.  If due to pilot failure, the thermocouple cools, no gas 
will  flow  to  the  main  burner.    If  the  fire  is  turned  off  or  the  flames  go  out,  wait  for  AT 
LEAST 3 MINUTES
 before attempting to relight the fire. 

 

When the fire is first lit, the flames tend to be rather blue in colour.  Once the core of the 
fire  becomes  hot,  the  flames  will  become  yellow  and  more  lifelike.    During  this  initial 
warm-up period it is recommended that the control remains in the ‘MAX’ position.  This 
permits the fire to reach its optimum condition more quickly. 

 

Read  carefully  the  LIGHTING  THE  APPLIANCE  for  the  relevant  model  in  section  9  of 
these instructions 

Summary of Contents for EARDF16NG

Page 1: ...TE GARDE Radiant HE Power flue gas fire MODEL NUMBERS EARDF16NG EARDF16P INSTALLATION SERVICING AND USER INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER 0120 THIS APPLIANCE MEETS THE REQUIRE...

Page 2: ...your fire 16 28 Assembling the fire and laying ceramic coals pebbles 17 Guarantee 17 Installation Service Record 19 Important Notes Please read before undertaking the installation 1 This is not a Do i...

Page 3: ...in a separate box which is inside the adapter box carton Any extra ducting elbows and fitting components will be packed in a separate carton 1 APPLIANCE DATA EARDF16NG EARDF16P GAS TYPE NATURAL GAS P...

Page 4: ...lage test there is no requirement for purpose made ventilation into the room containing the appliance See Section 14 5 FLUE TERMINAL POSITION The minimum distances permissible from the flue terminal t...

Page 5: ...ed the floor of the recess to the level of the hearth to allow accurate fitting of the firebox 4 Cut a hole through the cavity wall to accept the flue duct The centre line for the duct is 483mm 19 abo...

Page 6: ...Care should be taken to sleeve the pipe when passing through masonry 3 Connect the pipe to the burner at the isolation pressure test elbow using the nut and olive provided 4 When routing the gas supp...

Page 7: ...oint where the edge of the gasket is level with the inner flue duct 7 Secure the cable gland to its bracket on the fan carrier See Figure 7 and then connect the power cable using the Molex snap connec...

Page 8: ...ce the spacer against the wall ensuring it is correctly aligned with the flue duct and mark the position of the four fixing holes on the wall See Figure 7 Drill and plug the wall at these positions Ch...

Page 9: ...the underside of the burner unit to the mating plug on the switch panel of the fire See Figure 9 4 Place the burner tray in position within the firebox The tabs on either side of the rear of the burne...

Page 10: ...itch 2 Connect the electrical mains supply to the appliance turn on the gas supply and switch on the fire 3 From outside block the flue opening on the fan unit Initially the fan should be heard to spe...

Page 11: ...est firmly against the rear ceramic ROW C Place five large pebbles along the top of the raised slotted part of the base ceramic at the front of the burner These pebbles should be positioned so that th...

Page 12: ...he controller will shut down the whole system In this event the fire will go out and will only relight if the ON switch on the switch panel is pressed When first switched on the fan may pulse between...

Page 13: ...ft brush 4 Badly damaged coals pebbles should be replaced Replacement fuel pieces are available from our stockists 5 Check that there is no impairment to the electrode spark or pilot burner 6 Check th...

Page 14: ...ith an electronic control unit that monitors the behaviour of the fan during the start up procedure and in the event of high gusts of wind When the fan is switched on the controller will set it to run...

Page 15: ...liance is fitted with a flue blockage device that will shut off the appliance in the event of abnormal flue conditions This device is NOT a substitute for an independently mounted carbon monoxide dete...

Page 16: ...uld light the pilot burner If the pilot does not light try again after a few seconds The pilot may not light at the first attempt Waiting a few seconds gives the spark generator time to recover 5 Once...

Page 17: ...IRE AND LAYING CERAMICS COALS PEBBLES When laying the ceramics coals pebbles on the burner closely follow the instructions found on pages 11 12 of these instructions Failure to do so will possibly cau...

Page 18: ...e Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 5th SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 6th SERVICE Serviced by CORG...

Page 19: ...19 Be Modern Limited WESTERN APPROACH SOUTH SHIELDS TYNE WEAR NE33 5QZ TEL 0191 4553571 FAX 0191 4565556 Web site www bemodern com Email sales bemodern com THIS BOOKLET CONTAINS 20 PAGES HEPF BM 0606...

Reviews: