BE-SGGxxx USER MANUAL
17
STOP-SWITCH ADJUSTMENT
WARNING
Never attempt to alter, modify or override this switch.
If stop-switch ever needs to be replaced or adjusted follow the below directions.
Loosen Hex Nut.
1. Turn the Linkage Bolt clockwise to lower or counter-clockwise to raise the point of interaction with
Stop Switch. To set the proper interaction distance, grip the Operator Presence Bar & Handle Bar
together and lower the Linkage Bolt onto the Switch Button until the switch button cannot be
depressed any further.
Then raise the linkage bolt one turn (counterclockwise).
2. Tighten Hex Nut.
3. Verify operability of stop switch before operating machine by releasing the operator presence bar
next to the handle bar. You should hear a “CLICK”, signifying that the Linkage Bolt has been adjusted
properly.