
59
Troubleshooting
MAB 485
ENGLISH
Troubleshooting
Faults - causes and remedies
Fault
Possible cause
Remedy
The motor does not start
after pressing the ON/
OFF switch or stops during
operation.
Plug not inserted into socket. Insert plug.
Automatic circuit breaker
tripped.
Switch on the automatic circuit
breaker again.
The magnetic clamp is not
switched on.
Switch on the magnetic clamp.
The internal safety switch
has switched off the machine
due to overheating.
Allow the machine to cool
down.
Direction of rotation not
selected.
Preselect direction of rotation.
The automatic circuit
breaker in the electrical
distribution board trips
Too many appliances con-
nected to the same power
circuit.
Reduce the number of appli-
ances on the power circuit.
Machine is defective.
Contact After-sales Service.
The magnetic clamp does
not function.
Magnet not switched on.
Switch on magnet.
The surface is not magnetic.
Use a suitable base.
The lubrication system
does not function.
No lubricant available.
Top up the lubricant.
Lubricant tap closed.
Open the lubricant tap.
Connecting nipple clogged.
Clean tank and nipple.
NOTE
If you cannot resolve the problem with the steps described above, please contact
►
After-Sales Service.
Summary of Contents for MAB 485
Page 153: ......