BCF Technology DUOSCAN 3 User Manual Download Page 11

11

2  Care and maintenance

The Duo-Scan 3 was designed for reliability in the animal husbandry marketplace. BCF engineers 
and their appointed agents are available to provide rapid service assistance to ensure optimum 
performance of BCF systems. however there is no substitute for careful usage. 

As specialists in providing ultrasound imaging equipment for animal husbandry applications, 
we understand the importance of having reliable equipment. All BCF products are designed and 
manufactured to withstand the environments in which they are going to be used. However, should you 
experience any problems with your Duo-Scan 3, BCF Service Engineers will be available to provide rapid 
service support and ensure optimum performance of your BCF system.

The Duo-Scan 3 is designed to be robust and reliable and to withstand the environment in which it will 
be used. Should you experience any problems, BCF Service Engineers are available to provide rapid 
service support and ensure optimum performance. 

 
2.1 AxIAL AnD rADIAL PrOBe

•  Always clean the probe immediately after use and before any contamination can dry in.  

The probe head can be immersed in warm (not hot) water to clean.

•  The probe connector carries critical pulses from the console to the probe head and back. It is 

imperative to keep these contacts clean and free of contamination. To maintain a good contact, 
clean the connectors using methylated spirits (or equivalent alcohol) and a small toothbrush to 
gain access to the contacts, flush with alcohol and leave to drain hanging downwards.

•  Never force a connector if it will not go together easily. Debris may collect between the pins and 

can be carefully removed with a small screwdriver. 

•  Be very careful to avoid anything getting into the gold plated connector inserts, this may cause 

damage and some of these are expensive to replace.

•  Do not knock or scrape the transducer window, this may cause the window to burst. Do not push 

against the probe window, the sealing may be damaged or fluid may be forced out of the internal 
expansion tube. If a window or its seal leaks then the probe must be returned to BCF. Further use 
of the probe with a window leakage will further damage other internal parts of the probe due to 
dirt from outside contaminating the internal gears.

•  Do not forcibly bend or pull the cable connecting the probe to the module.

•  Examine the probe regularly for any damage, especially the window. The chamber behind the 

window is filled with a silicon fluid and it is normal for a small bubble, about 1mm diameter, to be 
present. A large bubble or signs of leaking fluid should be referred to a BCF Service Engineer.

•  Any other problems or maintenance queries should be referred to a BCF Service Engineer.

Duo-Scan 3 manual.indd   11

15/06/2009   21:38

Summary of Contents for DUOSCAN 3

Page 1: ...User manual Duo Scan 3 Duo Scan 3 manual indd 1 15 06 2009 21 38...

Page 2: ...1 4 Scanning 8 1 4 1 Standard operation 8 1 4 2 Mode selection 9 1 4 3 Gain and power adjustment 9 1 4 4 Freeze image 9 1 5 Battery life metering and charging 10 2 Care maintenance 11 2 1 Axial and ra...

Page 3: ...om Website www bcftechnology com As specialists in providing ultrasound imaging equipment for animal husbandry applications we understand the importance of having reliable equipment All BCF products a...

Page 4: ...ity and will ensure long life and continued safety Higher charge rates from unsuitable chargers may lead to hazards from fire or battery leakage in addition to reducing battery life Although the Duo S...

Page 5: ...3 accessories allow the ultrasound image to be viewed on the display headset monitor or wrist mounted display options Before connecting an imaging display device be sure the connector is free from dir...

Page 6: ...stem initialisation If the probe is connected it will start to rotate If the imaging display device is connected its screen will be illuminated The sector scan and settings will be displayed on the sc...

Page 7: ...intensity for the ultrasound picture 3 The current function of the soft keys is displayed along the bottom of the screen The menu disappears after approximately 6 seconds leaving only the scan voltage...

Page 8: ...e console are set using the front panel keys shown below SETTING SELECT FREEZE Scrolls through preset Modes Switches between Power or Gain Power or Gain down Power or Gain up Short press freezes image...

Page 9: ...ed so the information provided above may vary The shorter ranges are for use in early pregnancy and for improved detail the longer ranges for late pregnancy and better penetration As the range is alte...

Page 10: ...of the display this is primarily for factory use Charging The battery must first be removed from the Duo Scan 3 before charging Attach the battery to the charger by securing both latches Once the batt...

Page 11: ...keep these contacts clean and free of contamination To maintain a good contact clean the connectors using methylated spirits or equivalent alcohol and a small toothbrush to gain access to the contact...

Page 12: ...l toothbrush to gain access to the contacts flush with alcohol and leave to drain dry The outer case and PVC carrying case can be cleaned using a cloth warm soapy water The front panel can be cleaned...

Page 13: ...Physical Dimensions mm 280 D x 195 W x 95 H Weight 3Kg with battery Application preset modes Up to 8 different preset modes Probes 3 5 and 5 0 MHz radial scan probe 170 degree only Length 16 3 5 MHz a...

Page 14: ...m BCF Technology USA 2625 Highway 14 West Suite K Rochester Minnesota 55901 USA Tel 1 800 210 9665 Fax 1 507 529 8205 Email usa bcftechnology com Web www bcftechnology com BCF Ultrasound Australasia P...

Page 15: ...15 Accessories Rectal Probe Goggles Wrist Display Video Cable Axial Probe Batteries and charger Monitor Carry Sack Duo Scan 3 manual indd 15 15 06 2009 21 38...

Page 16: ...Duo Scan 3 www bcftechnology com Duo Scan 3 manual indd 16 15 06 2009 21 38...

Reviews: