PRO BLE
P
M
OSSI BLE C AUSE
SOL UT I ON
Sudden drop in gas flow
or reduced flame height.
Out of gas
Call your local
gas comp any
.
Excess flow safet y device
may have b e en activated
.
Refer to the ”Excess flow
safet y valve reset” p rocedure
on p age 31.
Irregular flame pattern,
flame does not run the f
ull length of burner.
Burner p orts are clogge d
or b locked.
Clean burner p or ts
.
Flame is yellow or orang e.
New burner may have
residual manufacturing oils.
Burn grill for 15 minutes
with the lid close d.
Spider webs or inse ct nest
in venturi.
Clean venturi.
Food residue, gre ase or
seasoning salt on b urner.
Clean b urner.
Poor alignment of valve to
burner venturi.
Ensure burner venturi is
prop erly engage d with
valve.
Flame blew out.
High or gusting winds.
T ur n f r ont of gr ill t o f ace
wind or inc r eas e f l ame
h eight .
Low on nat ural gas.
Call your local
gas comp an
y.
Excess flow valve tripp e d.
Refer to the ”Excess flow
safet y valve reset” p rocedure
on p age 31.
Flare-up.
Gre ase b uild - up
.
Clean gril
l.
Excessive fat in me at
.
Trim fat from meat b efore
grilling.