background image

 

 

10.4

 

A

LARM 

D

EVIATION 

 

 

If the temperature of the pit deviates above the setpoint by the alarm deviation setpoint, an alert will display in 
the application. The alarm deviation is settable from 10°F to 100°F and the factory default is 25°F. Change the 
alarm deviation from the Alarm Settings in the menu.  

10.5

 

S

MART 

C

OOK 

A

DAPTIVE 

C

ONTROL 

S

TRATEGY

 

The DynaQ’s Smart Cook Adaptive Control Strategy is designed to operate with a wide variety of pits by 
continually learning what the pit is doing and adapting to many factors including ambient temperature, amount 
of charcoal, damper settings, and more.  

For the DynaQ to work properly and determine how to adapt, the temperature inside the pit cannot oscillate up 
and down, and the lid or door must stay closed. If the lid or door is opened often, particularly on startup, the 
control cannot be expected to maintain setpoint. If the lid is left closed for approximately 10-20 minutes, the 
temperature will become stable after the control adapts. If the lid has been shut for at least 20-30 minutes and 
the temperature is going up and down significantly (± 10°F or more), the fan damper needs to be closed more.  

The Smart Cook feature allows you to tailor the adaptive algorithm to suit your specific pit with 3 preset 
options.  

Setting 1: Default setting. This setting is ideal for small, medium and some large ceramic cookers, traditional 
kettles, and small cabinet smokers. This version of the algorithm is the most popular for typical pits and uses 
averages to cycle the fan proportionately until it reaches the pit setpoint.  

Setting 2: This setting is ideal for very efficient or insulated pits like the Monolith. On setting 2, the fan will 
operate at 100% for a lesser amount of time before starting to cycle the fan at fewer intervals, until it reaches the 
pit setpoint.  

Setting 3: This setting is ideal for uninsulated or offset pits that are less efficient than an average pit such as a 
bullet smoker or common horizontal offset smokers. On setting 3, the fan will operate at 100% for a longer 
amount of time before starting to cycle the fan at more frequent intervals, until it reaches the pit setpoint. 

To change the Smart Cook feature, select option 1, 2 or 3 from the Controller Settings in the menu.  

10.6

 

C

OUNTDOWN 

T

IMER

 

The application is built with a countdown timer and there are three different options that you can select from 
when the timer runs out.  

From the main application screen, touch the Timer to set hours, minutes and seconds. On the same page in the 
application, also select your desired Timeout Action.  

Summary of Contents for DynaQ

Page 1: ...DynaQ User Guide...

Page 2: ...ounting to the Monolith Grill 7 8 Real Time Visual Pit Status 8 9 Connecting to a Bluetooth Enabled Device 10 10 Using the Mobile Application 11 10 1 Monitoring and Setting Temperature Setpoints 11 10...

Page 3: ...at temperatures low enough to avoid ignition EXPLOSION HAZARD SMOKER CAN COMBUST WHEN OXYGEN IS INTRODUCED AND PRODUCE SEVERE BURNS Use caution when opening the lid or door of the pit WARNING THERE AR...

Page 4: ...ber and date of purchase to customerservice thebbqguru com Failure to follow these instructions may prevent or delay your refund or exchange Items must be in a condition that permits resale BBQ Guru w...

Page 5: ...ontrol Push the plugs into the receptacles so that they physically and audibly snap in place If the probes are not plugged in securely there may be erratic temperature readings and the DynaQ will not...

Page 6: ...ll the way for cold smoking 7 PATENT PENDING 5 IN 1 MAGNETIC CONTROL MOUNT The DynaQ should be placed in a stable position in its stand The control can be rotated to face any direction and can sit at...

Page 7: ...embly requires the hex bolt thumb nut and upper control bracket from the 5 in 1 magnetic mount that was included with the control 1 Attach the sheet metal mount to the left side shelf by placing the P...

Page 8: ...to the jack so that it snaps into place If the indicator light still does not go on this may indicate that you have a bad or erratic probe The outer ring of the control will illuminate in a variety of...

Page 9: ...s are not pulsing or are pulsing infrequently close the fan damper slightly If the pit temperature is above the set temperature by its deviation range the outer light ring will pulse red continuously...

Page 10: ...To reset the control to its factory defaults hold down the button on the left side of the control for 4 seconds or see Section10 Using the Mobile Application 9 CONNECTING TO A BLUETOOTH ENABLED DEVIC...

Page 11: ...ures The default pit temperature is 250 F and the default food temperature is 185 F As long as the control remains within Bluetooth range the application will always show the actual temperature readin...

Page 12: ...done temperature NOTE The controller will hold the pit temperature slightly above the food done setpoint as long as there is fuel This is to account for natural evaporative heat loss If the pit tempe...

Page 13: ...you to tailor the adaptive algorithm to suit your specific pit with 3 preset options Setting 1 Default setting This setting is ideal for small medium and some large ceramic cookers traditional kettles...

Page 14: ...t at the bottom as this may cause the pit to overfire during startup Normally the DynaQ will be able to adjust the fan airflow accordingly to deliver precise control so no damper adjustment will be re...

Page 15: ...eal time temperature readings Check if the Bluetooth LED indicator light on the DynaQ is solid blue If it is blinking it no longer has a Bluetooth connection The pit temperature is going higher than t...

Page 16: ...s exposed to direct flame or excessive temperatures Purchase a new probe at bbqguru com 13 CONTACT BBQ GURU BBQ Guru 359 Ivyland Road Warminster PA 18974 https bbqguru com customerservice thebbqguru c...