BAYKON TX 1 Operational Manual Download Page 3

 

1.  Features 

 

The  amplifier  type  TX  1  is  an  accurate  and  economic  load  cell  transmitter,  easy  to 
integrate  into  process  control  systems.  By  its  “digital  heart”  –  modern  microcontroller 
technology – type TX 1 allows a comfortable calibration and set up with a combination of 
LED’s and push buttons. Option equipped TX 1 can be programmed and calibrated via PC 
software xFace. 

 

The analogue signal output is programmable to 0 – 10 V or 4 – 20 mA. An opto-isolated 
interface option offers 2 setpoints, 1 error output, 1 input for zeroing by external command 
and one RS232C serial data output for setup & calibration. 

 

TX 1 has important advantages listed below:  

  It  is  a  rail  mounted  device  which  can  be  easily  installed  in  control  panels.  Its 

physical dimensions allow reasonable space advantage in the panel.   

  Very easy and user friendly digital adjustment and programming via keys located on 

the front panel.  

  In  case  of  Error,  user  is  warned  by  Error  LED  on  front  panel  and  optional  Error 

output signal is activated. Analogue output goes out of the operating range. 

  Via optional zeroing input, TX 1 can be zeroed by PLC or any other external device. 

  eCal calibration and setup without weights via optional serial port and PC software. 

 

1.1. Technical Specification 

 

INPUT  &  A/D CONVERTER 

Linearity 

% 0.01 or better 

Analogue input range  0 mV to 20 mV 
Min. input range 

 < 1 mV 

A/D Converter  

24 bit Delta-Sigma ratiometric with integral analog and digital filters 

Resolution 

Min. 0.50 

µ

V/count 

Internal resolution 

Min. 8 000 000 counts 

Conversion rate 

Up to 100 measurements per second at TX 1 
Up to 400 measurements per second at TX 1W 

SCALE CALIBRATION & ANALOGUE OUTPUT 

Calibration 

Performed with keys. There is no any switch or resistor for adjustment in 
the instrument 

Digital Filter 

2 step adjustable digital adaptive filter at TX 1 
9 step adjustable digital adaptive filter at TX 1W 

Weighing Functions 

Zeroing via opto-isolated digital input (only TX 1W) 

D/A Converter  

16 bit 

Analogue output 

Current output 4-20 mA or voltage output 0-10 V 

Set point  

2 programmable free setpoints (only TX 1W) 

input / output 

2 opto-isolated outputs for setpoints and 1 opto-isolated input for zeroing 
(only TX 1W) 

LOAD CELLS 
Excitation 

5 V DC 

Number of Load Cells  Up to 4 units of 350 

 or 12 units of 1100 

  (min. 85 

Connection 

4 or 6 wire technique. Cable length 274 m/mm² for 6 wire connection 

SETUP & COMMUNICATION 
Front panel 

Membrane keypad including  2x LED and 3x programming keys 

eCal 

Calibration without weights by PC software (only TX 1W) 

POWER 
Power supply 

230 V AC, 50 Hz , 6 VA  or   24 VDC  0.2 A  

ENVIRONMENT AND ENCLOSURE 
Operation Temperature Between -10 °C and +40 °C at 85% RH max, non-condensing 
Enclosure 

Polyamide, for DIN-rail mount, IP20 

Summary of Contents for TX 1

Page 1: ...TX 1 WEIGHT TRANSMITTER OPERATIONAL MANUAL 08 2012...

Page 2: ...C only TX 1W 5 2 7 Commissioning 6 3 Operation 6 4 Programming via Keys 6 4 1 Changing the Analogue Output Mode 7 4 2 Setup and Calibration 7 5 Programming by PC software 10 6 Housing Dimensions 11 7...

Page 3: ...PUT A D CONVERTER Linearity 0 01 or better Analogue input range 0 mV to 20 mV Min input range 1 mV A D Converter 24 bit Delta Sigma ratiometric with integral analog and digital filters Resolution Min...

Page 4: ...pment that produces electrical noise Place your transmitter in a separate metal panel from the frequency converters and motor contactors or at least place it in another partition of the panel Do not c...

Page 5: ...beside its safety If the condition of the power line in the plant is bad prepare a special power line and grounding If you have to service the instrument turn off the power and wait at least for 30 s...

Page 6: ...g input the analogue output signal of TX 1W will be set to 0 kg The setpoints will be active when the weight value is higher than the entered setpoint value If any failure occurs within TX 1W an error...

Page 7: ...ow 4 Programming via Keys After making the connections of TX 1 as described before energize the transmitter During power on period green and red LEDs are lightened for 3 second After turning off both...

Page 8: ...can follow the selected mode by lightened LED If you have changed the analogue output mode you have to recalibrate the transmitter regardless if it has already been calibrated for the other output mod...

Page 9: ...o the next step by pressing the key Calibrate the scale and adjust other parameters as indicated below STEPS LED s POSITION DESCRIPTION GREEN RED SPAN ADJUST KAZAN AYARI Flash Flash Load the scale The...

Page 10: ...crease the output value very high rate Pressing this key will increase the output value Pressing this key continuously will increase output faster While pressing this key continuously pressing key wil...

Page 11: ...Cal values to the transmitter button easily The minimum PC requirements are Windows 2000 Windows XP or Windows Vista operating system Serial port Serial cable for RS232C signals between TX 1W and PC F...

Page 12: ...the output mode is set to 4 20 mA the ERR LED lights continuously in case of an error If the analogue output mode is set to 0 10 V the ERROR LED flashes FRONT PANEL LEDS Run Green LED Error Red LED E...

Page 13: ...12 Notes...

Page 14: ...BAYKON A Kimya Sanayicileri Organize Sanayi B lgesi Organik Cad No 31 Tepe ren 34956 stanbul T RK YE Tel 0216 593 26 30 pbx Fax 0216 593 26 38 e mail baykonservis baykon com http www baykon com...

Reviews: