BAYKON TX 1 Operational Manual Download Page 1

                  

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 

T

 

X 1     

WEIGHT TRANSMITTER 

OP E R A T I ON A L   MA N U A L  

                       

 

 

 

 

 
 
 

08/2012 

 

Summary of Contents for TX 1

Page 1: ...TX 1 WEIGHT TRANSMITTER OPERATIONAL MANUAL 08 2012...

Page 2: ...C only TX 1W 5 2 7 Commissioning 6 3 Operation 6 4 Programming via Keys 6 4 1 Changing the Analogue Output Mode 7 4 2 Setup and Calibration 7 5 Programming by PC software 10 6 Housing Dimensions 11 7...

Page 3: ...PUT A D CONVERTER Linearity 0 01 or better Analogue input range 0 mV to 20 mV Min input range 1 mV A D Converter 24 bit Delta Sigma ratiometric with integral analog and digital filters Resolution Min...

Page 4: ...pment that produces electrical noise Place your transmitter in a separate metal panel from the frequency converters and motor contactors or at least place it in another partition of the panel Do not c...

Page 5: ...beside its safety If the condition of the power line in the plant is bad prepare a special power line and grounding If you have to service the instrument turn off the power and wait at least for 30 s...

Page 6: ...g input the analogue output signal of TX 1W will be set to 0 kg The setpoints will be active when the weight value is higher than the entered setpoint value If any failure occurs within TX 1W an error...

Page 7: ...ow 4 Programming via Keys After making the connections of TX 1 as described before energize the transmitter During power on period green and red LEDs are lightened for 3 second After turning off both...

Page 8: ...can follow the selected mode by lightened LED If you have changed the analogue output mode you have to recalibrate the transmitter regardless if it has already been calibrated for the other output mod...

Page 9: ...o the next step by pressing the key Calibrate the scale and adjust other parameters as indicated below STEPS LED s POSITION DESCRIPTION GREEN RED SPAN ADJUST KAZAN AYARI Flash Flash Load the scale The...

Page 10: ...crease the output value very high rate Pressing this key will increase the output value Pressing this key continuously will increase output faster While pressing this key continuously pressing key wil...

Page 11: ...Cal values to the transmitter button easily The minimum PC requirements are Windows 2000 Windows XP or Windows Vista operating system Serial port Serial cable for RS232C signals between TX 1W and PC F...

Page 12: ...the output mode is set to 4 20 mA the ERR LED lights continuously in case of an error If the analogue output mode is set to 0 10 V the ERROR LED flashes FRONT PANEL LEDS Run Green LED Error Red LED E...

Page 13: ...12 Notes...

Page 14: ...BAYKON A Kimya Sanayicileri Organize Sanayi B lgesi Organik Cad No 31 Tepe ren 34956 stanbul T RK YE Tel 0216 593 26 30 pbx Fax 0216 593 26 38 e mail baykonservis baykon com http www baykon com...