background image

DATE:

CLIENT:

DESCRIPTION:

SCHAWK JOB#:

SKU#:

DIMENSIONS:

PRINTER SPEC:

RELEASE: V-7

LANGUAGE(S):

ENGLISH

INTERNAL: R-0

18211 NE 68th Street, E120 
Redmond, WA 98052 
T: 425-881-5454

BAN#:83791927  

Rev. 02/12

Contour NEXT EZ User Guide US English
Alt#1 - 02/20/12 cpy chg; Alt#7-3/29/12 cpy ch
Alt#2 - 02/22/12 copy changes
Alt#3 - 02/23/12 copy changes
Alt#4 - 03/02/12 copy changes
Alt#5 - 03/09/12 copy changes
Alt#6 - 03/26/12 copy changes

March 29, 2012
Bayer HealthCare
Contour NEXT EZ User Guide - US English

908191
7252, 7253, 9628, 9629
6.0” (H) x 4.5” (W)
PUSG0494 REV G

FONTS:

Helvetica, HelveticaNeueRed, Zapf Dingbats

COLORS:

 Cyan

 

 

Magenta 

 

Yellow 

 

Black

NOTE: THIS COLOR PROOF INDICATES COLOR BREAK ONLY AND MAY NOT ACCURATELY REFLECT ACTUAL PRODUCTION COLOR.

Regional Master Template No: M_GDE_USR_0208 R0003

Clinical Trial / Global Master Template No: XXXX

®

USER GUIDE

Blood Glucose 
Monitoring System

FC: 18.3 mm   BC: 7 mm
Footer: 7 mm
1/3rd of Cross clear 

space has been applied

7mm min.

83791927_CntrNextEZ_UG_EN_FpBp_v7.indd   ofc1

83791927_CntrNextEZ_UG_EN_FpBp_v7.indd   ofc1

3/29/12   3:15 PM

3/29/12   3:15 PM

Summary of Contents for Contour Next EX

Page 1: ...USER GUIDE Blood Glucose Monitoring System...

Page 2: ...of glucose in whole blood is for single patient use only and should not be shared The CONTOUR NEXT EZ blood glucose monitoring system is indicated for use with fresh fingertip capillary whole blood sa...

Page 3: ...Advanced Mode 39 Error Codes and Symbols 42 Changing the Batteries 47 Caring for Your Meter 49 Symptoms of High or Low Blood Glucose 50 Specifications 51 Service Information 57 Warranty 58 Supplies 61...

Page 4: ...presenting date and time Pre meal result marker Post meal result marker Identifies a Logbook entry Indicates a reminder has been set Center area on the display that shows either your test result or an...

Page 5: ...Example or Check your display to ensure that results are being displayed in mg dL If they are not contact Bayer Diabetes Care Customer Service at 1 800 348 8100 available 24 hours a day 7 days a week...

Page 6: ...than One Person Poses Risk for Transmitting Bloodborne Pathogens 2010 http www cdc gov injectionsafety Fingerstick DevicesBGM html Important Safety Information Important Safety Information Important...

Page 7: ...dent as shown 5 Replace the gray endcap prior to getting your blood drop 6 The puncture depth depends on the endcap setting and the amount of pressure applied to the puncture site You will determine w...

Page 8: ...op and Testing 2 Stroke your hand and finger towards the puncture site to form a drop of blood Do not squeeze around the puncture site 3 Test immediately after a good blood drop has formed Suggested d...

Page 9: ...g Your Blood 5 After a beep you will see the meter count down 5 seconds and your blood test result is displayed and automatically stored in the meter memory Please do not touch the test strip during t...

Page 10: ...ion of infectious diseases Your CONTOUR NEXT EZ system should be cleaned of dirt and debris once a week Disinfecting if performed properly reduces the risk of transmitting infectious diseases Your met...

Page 11: ...Risk for Transmitting Bloodborne Pathogens Initial Communication 2010 http www fda gov MedicalDevices Safety AlertsandNotices ucm224025 htm CDC Clinical Reminder Use of Fingerstick Devices on More th...

Page 12: ...ning 0 55 sodium hypochlorite bleach Paper towels Timing device 1 Before disinfecting clean the lancing device as described above in Cleaning Your Lancing Device 2 Remove the endcap and lancet if pres...

Page 13: ...need help locating CONTOUR NEXT control solutions call Bayer Diabetes Care Customer Service at 1 800 348 8100 available 24 hours a day 7 days a week 1 Wash and dry your hands well before and after tes...

Page 14: ...t result is within the specified range It only marks it as a control solution test It will not be included in your averages 9 Compare your control test result to the ranges provided on the test strip...

Page 15: ...The number in the hour position will now flash Press or until you reach the current hour Press M to set The minute will now flash Press or to select the current minute Press M to set If you selected...

Page 16: ...Modes 7 day HI and LO summary 14 day average 480 test result memory 7 day HI and LO summary 7 14 and 30 day averages 480 test result memory Pre and post meal markers 30 day pre and post meal averages...

Page 17: ...ed Advanced Mode L 2 on your display you can change your meter s personal low and high blood glucose settings By personalizing these settings your CONTOUR NEXT EZ meter will help you track these HI an...

Page 18: ...u test your blood Pre meal Marks a test result that was taken before a meal Post meal Marks a test result that was taken after a meal Logbook The logbook marker can be used to mark any result as being...

Page 19: ...en you have completed this test and the result is shown on the display will flash To mark this test as a post meal result press M If you do not want to mark this test remove the test strip to turn the...

Page 20: ...st meal test Logbook Press or Flashing Press M Result is marked in memory as unique You should note this in your logbook Post meal glucose measurements should be made 1 2 hours after the beginning of...

Page 21: ...tware GLUCOFACTS Deluxe and a data cable from Bayer For a free download of the software go to www bayerglucofacts com or call Bayer Diabetes Care Customer Service at 1 800 348 8100 available 24 hours...

Page 22: ...d as a new test is completed and saved to the memory Press M to turn the meter off or it will automatically turn off after 3 minutes represents the number of test results Viewing Advanced Mode Results...

Page 23: ...igh and low summary At the top of the display you will see the number of HI and LO results In the center of the display is the total number of results Press M to turn your meter on Press M again to vi...

Page 24: ...ime This error occurs only in Communication mode See pages 24 25 to reset the date or time If you continue to see this error please contact Bayer Diabetes Care Customer Service at 1 800 348 8100 avail...

Page 25: ...etest using a new test strip Be sure you wash and dry your hands well and carefully follow instructions in this user guide Only Bayer s CONTOUR NEXT test strip should be used Test result is above 600...

Page 26: ...2 If the display is not correct contact Bayer Diabetes Care Customer Service at 1 800 348 8100 available 24 hours a day 7 days a week Results are not displayed in expected units of measure mg dL This...

Page 27: ...r Your Meter Store meter in the carrying case provided whenever possible Wash and dry hands well before handling to keep the meter and test strips free of water oils and other contaminants Handle the...

Page 28: ...T 77 mm H x 57 mm W x 19 mm T Weight 1 7 oz 47 5 grams Sound A beep sounds when the meter is turned on a test strip is inserted when a test strip is filled with blood or when a test result appears on...

Page 29: ...s displayed No calculation is required Comparison Options The CONTOUR NEXT EZ system is designed for use with capillary whole blood Comparison to a laboratory method must be done simultaneously with a...

Page 30: ...curacy results for glucose concentration 75 mg dL Difference range in values between YSI laboratory reference method and CONTOUR NEXT EZ meter Within 5 mg dL Within 10 mg dL Within 15 mg dL Number and...

Page 31: ...this user guide help contact Bayer Diabetes Care Customer Service at 1 800 348 8100 available 24 hours a day 7 days a week We have trained specialists to help you Important Speak to a Bayer Diabetes C...

Page 32: ...tes Care instruments caused by the use of reagents other than the appropriate Bayer reagents e g CONTOUR NEXT test strips manufactured or recommended by Bayer Diabetes Care 3 Bayer Diabetes Care reser...

Page 33: ...tml 3 Longo DL et al Harrison s Principles of Internal Medicine 18th edition 2011 3003 4 American Diabetes Association Clinical Practice Recommendations Diabetes Care 2011 34 1 S1 S96 5 American Diabe...

Page 34: ...83791927_CntrNextEZ_UG_EN_FpBp_v5 indd 62 63 83791927_CntrNextEZ_UG_EN_FpBp_v5 indd 62 63 3 9 12 2 54 PM 3 9 12 2 54 PM...

Page 35: ...com Bayer the Bayer Cross CONTOUR GLUCOFACTS MICROLET and the No Coding logo are registered trademarks of Bayer No Coding is a trademark of Bayer All other trademarks are the property of their respect...

Reviews: