54
CAPSULE HUB TROUBLESHOOTING GUIDE
Carousel Motor is hard
to turn by hand
Carousel motor should be easy to spin by hand. If it is hard to spin:
At power ON, pivot motor failed the home sensor test. Please refer to “Motor/
Sensor self test failed at power on” section below.
Binding in chain and/or sprockets.
Stepper motor itself is binding. Turn game off and see if binding continues.
Capsule
does not
Drop
Go to
Menu and
try “Test
Dispense”
Carousel
Motor is
not turning
Door Switch is Open
Pivot Motor Home Sensor
Inspect cables from Carou-
sel Stepper Motor to Stepper
Motor Board to 1803 board.
(AACE1812, AACB1801,
AACE1813, AAMO6901)
Faulty Stepper Motor Board
Faulty Stepper Motor
Check switch operation, inspect connections on
AACE1812 cable.
Go to Diagnostics in Menu to “Module Status
Information” - If it shows “Capsule Tree Door
Opened” then replace AACB1803 board in unit.
At power ON, pivot motor will cycle to test home
sensor. Please refer to “Motor/Sensor self test
failed at power on” section below.
Test for 12 Volts DC at Stepper Motor Board
Replace Stepper Motor Board (AACB1801)
Replace Stepper Motor (AAMO6901)
Carousel
Motor does
not slow
down
Carousel Home sensor is
blocked or faulty.
Disconnected, loose or
broken wires.
Faulty Sensor
Faulty Stepper Motor Board
Faulty Control Board
Check for 12 Volt DC between yellow and
blue wires. 5 Volts between blue and white
should drop to zero when blocked.
Check connections from sensor to AACB1800
board. Cables # AACB4401 and AACE1812
Replace AACB4401
Replace AACB1801
Replace AACB1803
Capsule
Engage
Motor is
not turning
After motors swing over, the
Individual capsule engage
motor will spin sprocket.
If motor does not turn, check
for 12 volts DC at motor.
If 12 Volts DC is ok:
Replace motor (AAMO4401)
If no12 Volts DC:
Check for disconnected, loose or broken wires.
(Cable #’s AAMO4401, AACE1812)
Replace Control Board (AACB1803)
Capsule
Engage
Motor is
turning
If motor is turning and no
capsules drop there must be
a jam inside unit.
Remove capsules and locate and clear jam.
12 Volt DC Power In
AACE1813
Troubleshooting Chart
Problem
Probable Cause
Remedy