Configuring the ARN for Netboot and Directed Netboot
114200 Rev. A
A-3
Frame Relay Settings
-fr
Configures the router COM interface as a Frame Relay connection.
With this setting, use one of the following options to specify a DLCMI
setting: -annexd,
-
annexa, or -lmi.
-annexd
-annexa
-lmi
When one of these options is used with the -fr setting, it specifies a
DLCMI setting. Use the same setting as the network to which the
router’s Frame Relay interface is connected. The default setting for
Frame Relay is -annexd.
Internal Clocking Setting
-int_clk
Sets the serial interface to internal clocking at 1.25 MB/s. If you do not
specify this setting, the router defaults to external clocking.
IP Connector Setting
<interface>
Specifies the IP connector you are configuring. Use the format
com<
port #>.
IP Address Settings
<IP address>
Specifies the IP address of the interface you set with
<interface>.
Provide this address in dotted decimal notation.
<subnet mask>
Specifies the IP subnet mask of the interface you set with
<interface>.
Provide this address in dotted decimal notation.
<next hop
address>
Specifies the IP address of the next-hop router. Provide this address
in dotted decimal notation. Specify this address only if there are
intermediate routers between the router and the BootP server.
Table A-1.
ifconfig Command Settings for a COM Interface
(continued)
Setting
Description