1.3
Specific safety instructions
Warning
Refrigerant fluid and pipes:
Only use R-134a refrigerant fluid to fill the
system.
Use tools and pipe components especially
designed for use with R-134a refrigerant fluid.
Use copper pipes deoxidised with phosphorus
to carry the refrigerant fluid.
Use beading to guarantee the tightness of the
connections.
Store the refrigerant connection pipes away
from dust and humidity (risk of damage to the
compressor).
Cover both ends of the pipes until the beading
process.
Do not use a load cylinder.
Regarding information on installation on the
appliance, electrical connection and connection
of the water circuit, refer to the paragraphs
below in this manual.
Regarding information on handling, servicing
and scrapping the appliance, refer to the
paragraphs below in this manual.
Caution
In order to limit the risk of being scalded, the
installation of a thermostatic mixing valve on the
domestic hot water flow pipes is recommended.
1.4
Liabilities
1.4.1
Manufacturer's liability
Our products are manufactured in compliance with the
requirements of the various Directives applicable. They
are therefore delivered with the marking and any
documents necessary. In the interests of the quality of
our products, we strive constantly to improve them. We
therefore reserve the right to modify the specifications
given in this document.
Our liability as manufacturer may not be invoked in the
following cases:
Failure to abide by the instructions on installing and
maintaining the appliance.
Failure to abide by the instructions on using the
appliance.