4. Connect the immersion heater power supply cable as shown in the
figure opposite.
5. Remove the safety thermostat bulb from the thermowell.
6. At the same time, insert the safety thermostat bulb (first) and then the
temperature sensor (further back) in the thermowell, at least up to the
mark (15 cm from the end of the sensor).
7. Feed the bulb capillary into the retaining lug on the left-hand side so
that it does not touch the immersion heater.
8. Route the temperature sensor cable into the retaining lug on the left-
hand side so that it does not touch the immersion heater.
Caution
Do not allow the sensor cable to touch the immersion heater.
9. Secure each cable with its traction arrester device on the upper part of
the appliance.
Fig.56
Immersion heater connection
MW-4000158-2
4
4
Fig.57
Fitting the sensor
MW-4000159-2
5
6
7
8
Fig.58
Tightening the traction arresters
MW-1001324-1
9
6 Installation
56
SPC Split
7740321 - v04 - 03122019