5.0 Installation
19
5.7
Fitting the Back Plate
1. Engage the assembly into the hole previously
cut in the wall and slide in place (Fig. 31).
2. Secure the assembly to the wall at the
previously drilled anchorage points with suitable
screws (Fig. 31). Before finally tightening the
screws, check that the assembly is level.
3. Make good between the wall and the air duct
outside the building if the internal fitting kit has
not been used (Fig. 32).
4. The flue trim provided may be fitted if required,
to neaten the make-up around the terminal
(Fig. 33).
5.
To fit the flue terminal trim:
a) The trim should be fitted once the flue is
secure.
b) Take the three edge clips from the kit and fit
them equi-spaced onto the inner flange of the
trim (Fig. 32a).
c) With the flanges towards the wall pass the trim
over the terminal. If required a bead of sealant
may be applied to the rear face of the trim.
d) Push firmly on the trim to ensure the edge clips
engage on the flue.
Fig. 31
Fig. 33
Fig. 32
Edge Clip
Flue Trim
Flue Trim
Fig. 32a