5.0 Installation
22
5.10
Fitting the Flue and Back Plate
1.
NOTE:
There are two options for fitting the
flue and back plate they are:
Method A
- Fitting the flue and back plate as an
assembly (usually used where there are no side
clearance problems).
Method B
- Pre-fitting the flue through the wall,
fitting the back plate to its position on the wall
and then connecting the two together (usually
used where side clearances are restrictive).
5.11
Method A
1. Remove the left or right hand air box blanking
plate, as appropriate, from the back plate air box
by releasing the three screws (Fig 46).
2. Rotate the turret to face the selected opening
(Fig. 47) and remove the side blanking cap by
pushing in and turning anti-clockwise to release
the bayonet fitting (Fig. 46).
3. Locate the flared end of the flue duct over the
bayonet fitting on the turret, taking care not to
damage the 'O' ring. Lock the flue in place by
pressing in and turning clockwise (Fig. 49).
4. Ensure that the 'O' ring seal is in position
against the sealing flange.
5. Fit the air duct over the flue duct and draw
towards the air box on the back plate. Engage
the bayonet slots of the air duct over the location
lugs of the back plate opening and press and
turn clockwise to secure the air duct to the air
box (Fig. 50).
6. In order to increase security of the flue, the
bayonet tags may be deformed to secure the
flue in position.
7. Take the flue terminal assembly and engage
on the flue and air ducts. Slide the flues together
to the desired flue length. Tape the outer duct
sections together with the tape provided
ensuring a good seal is made.
Fig. 46
Fig. 47
Fig. 49
Fig. 50
Turret
Air Box
Blanking Plate
Blanking
Cap
Flue Duct
Air Duct