9.4.2
Premium factory setting values
Solar
Tab.18 Factory values on the solar menu
Basic settings
System
1
Collector
Min. coll. temp.
10 °C
Safety limit
130 °C
Accumulator
ΔT
on
6.0K
ΔT
off
4.0K
ΔT
nom.
10.0K
Acc. nom. temp.
60 °C
Acc. max. temp.
60 °C
AccHys
2.0K
Increase
2.0K
t
min
30 s
Minimum speed
40%
Accumulator
Activated
Installation
Tab.19 Factory values on the installation menu
Optional functions
Parallelling relay
Relay
R4
Reference relay
R1
Extend
Deactivated
Delay
Deactivated
Speed
Deactivated
Reverse
Deactivated
Function
Activated
Energy meter
Tab.20 Factory values on heating menu
Energy meter
Feed flow sensor
S3
Return flow sensor
S6
Flow sensor
Activated
Flow sensor
S6
Fluid type
Water
Function
Deactivated
Inputs/Outputs
Tab.21 Factory values on the inputs menu
Inputs
S1
PT1000
S2
PT1000
9 Commissioning
7729335 - 04 - 12052021
Solar hydraulic unit
37