27
USER Section
(en)
7114043.01 (1-06/13)
317 162
Call the Authorised Service Centre.
Call the Authorised Service Centre.
321 163
Call the Authorised Service Centre.
Call the Authorised Service Centre.
384 164
Parasite flame (internal error)
Press and hold down for at least 2 seconds.
385 165
Input voltage too low
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.
5. BOILER INFORMATION MENU
Press and hold down
for at least 1 second, to display the information indicated in the table. Press
to exit.
DESCRIPTION
DESCRIPTION
00
Code interne erreur secondaire
06
Température retour chaudière (°C)
01
Température alimentation chaudière °C)
07
Température sonde fumées (°C)
02
Température extérieure (°C)
08
Température échangeur primaire (°C)
03
Température ECS ballon à chauffage indirect
(seulement chauffage central chaudière)
09 – 13
Informations du fabricant
04
Température eau chaude sanitaire
(chaudière avec échangeur à plaques)
14
Communication identification OpenTherm
05
Pression eau installation de chauffage (bar)
15 - 18
Informations du fabricant
6. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
7. FILLING THE SYSTEM
Regularly check that the pressure displayed on the pressure
gauge "
D
" is
1 - 1.5
bar, with the boiler cold. If the pressure is
too low, turn tap "
A
" to fill the boiler (figure to side).
A
Boiler filling tap
B
Storage boiler drain tap
C
Boiler drain tap
D
Pressure gauge
Take special care when filling the heating system. In
particular, open any thermostat valves in the system,
ensure the water enters slowly in order to prevent the
formation of air inside the primary circuit until operating pres-
sure is reached. Lastly, vent any radiators in the system. BAXI declines all liability for damage deriving from the presence of air bub-
bles in the primary exchanger due to the incorrect or imprecise observance of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED TECHNICAL SERVICE CENTRE.
8. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Summary of Contents for NUVOLA DUO-TEC GA 16
Page 21: ...21 7114043 01 1 06 13 ...
Page 41: ...41 I N S T A L L E R S e c t i o n e n 7114043 01 1 06 13 ...
Page 61: ...61 7114043 01 1 06 13 ...
Page 102: ...7114043 01 1 06 13 102 S E C T I O N A ...
Page 104: ...7114043 01 1 06 13 104 S E C T I O N B ...
Page 106: ...7114043 01 1 06 13 106 S E C T I O N C ...
Page 107: ...107 S E C T I O N D 7114043 01 1 06 13 25 mm ...
Page 109: ...109 S E C T I O N E 7114043 01 1 06 13 ...