23. technical data
Boiler model Luna ht
1.350
1.450
1.550
1.650
category
ii
2h3p
ii
2h3p
ii
2h3p
ii
2h3p
Rated heat input
kW
34,8
46,4
56,7
67,0
Reduced heat input
kW
15
15
16,0
20,0
Rated heat output 75/60°C
kW
33,9
45,0
55,0
65,0
-
kcal/h
29.150
38.700
47.300
55.900
Rated heat output 50/30°C
kW
36,5
48,7
59,5
70,3
-
kcal/h
31.390
41.880
51.170
60.460
Reduced heat output 75/60°C
kW
14,5
14,5
15,5
19,3
-
kcal/h
12.470
12.470
13.330
16.598
Reduced heat output 50/30°C
kW
15,8
15,8
16,8
21,0
-
kcal/h
13.588
13.588
14.450
18.060
Useful efficiency according to 92/42/CEE directive
—
★★★★
★★★★
★★★★
★★★★
Central heating system max. pressure
bar
4
4
4
4
Heating circuit temperature range
°C
25÷80
25÷80
25÷80
25÷80
Water content
l
5,1
5,1
5,6
6,5
Type
—
C13 - C33 - C43 - C53 - C63 - C83 - B23
Concentric flue duct diameter
mm
80
80
80
80
Concentric air duct diameter
mm
125
125
125
125
2-pipe flue duct diameter
mm
80
80
80
80
2-pipe air duct diameter
mm
80
80
80
80
Max. flue mass flow rate
kg/s
0,016
0,022
0,027
0,032
Min. flue mass flow rate
kg/s
0,007
0,007
0,008
0,010
Max. flue temperature
°C
72
74
78
75
NOx class
—
5
5
5
5
Type of gas used
—
G20
G20
G20
G20
—
G31
G31
G31
G31
Natural gas feeding pressure 2H (G20)
mbar
20
20
20
20
Propane gas feeding pressure 3P (G31)
mbar
37
37
37
37
Power supply voltage
V
230
230
230
230
Power supply frequency
Hz
50
50
50
50
Rated power supply
W
45
75
80
125
Net weight
kg
64
64
68
72
Dimensions
height
mm
950
950
950
950
width
mm
600
600
600
600
depth
mm
466
466
466
466
Protection-limit against humidity
and water leakages (**)
IPX5D
IPX5D
IPX5D
IPX5D
(**) according to EN 60529