9.1 Maintenance
IMPORTANT:
It is possible that some soot may be
deposited on the coals after use. This is acceptable
providing it is not allowed to accumulate.
CAUTION: The coals are extremely fragile and must be
handled accordingly. To avoid soiling ones hands,
gloves should be worn and any inhalation of the dust
should be avoided. Keep the coals away from children
at all times. Never use coals other than those supplied
or Genuine Baxi Spare Parts. Never put additional
coals on the fire. Please read
Section 1.2 Important Information
1. Servicing should be carried out regularly by a
competent person in accordance with the relevant
regulations, to ensure the safe and correct operation of the
appliance.
2. Before commencing any service or replacement of
parts, turn off the gas supply to the fire and ensure that the
fire is cold.
3. After servicing, check for gas soundness.
4. When ordering spare parts please quote appliance
name and serial number. These can be found on the data
badge which is located by removing the controls access
door, the badge is on the base plate of the appliance.
5. At least once a year check for debris in the catchment
area behind the fire and in the flueway.
6. If excessive soot has accumulated check to establish
the cause. Rectify and clean flue or chimney accordingly.
7. The loose coals may be removed for cleaning. The
coals are delicate and should be handled carefully. Gently
brush with a soft brush to remove dust or deposits.
8. Examine the coals for signs of cracking and replace if
necessary.
IMPORTANT: See coal layout procedure
(Section 6.0 Arranging the Coals) before attempting to
replace coals which should only be replaced as a
complete set with no extra coals added.